dc.description.abstract
Die Blutuntersuchung kann beim Rind einen entscheidenden Hinweis auf den
Gesundheitsstatus des Einzeltieres oder der Herde liefern. Die Analysemethoden
wurden in den letzten Jahren verfeinert und das Qualitätsmanagement in die
Labors eingeführt, so dass analytische Fehler stark zurückgegangen sind. Die
vorliegende Studie sollte Rahmenbedingungen für den ex vivo-Umgang mit
Blutproben liefern und so einen Beitrag zur Qualitätssicherung in der
Rinderpraxis leisten. In diesem Zusammenhang wurde der Einfluss
unterschiedlicher Blutentnahmesysteme und Transportbedingungen auf die
Serumgehalte ausgewählter Stoffwechselparameter untersucht. Für den Vergleich
verschiedener Blutentnahmesysteme wurden Serum-Monovetten®, die sowohl offen
als auch geschlossen zum Einsatz kamen, und Vacutainer® mit und ohne Trenngel
verwendet. Im Serum wurden zum Teil statistisch signifikante Unterschiede in
den Parametergehalten festgestellt, was mit den unterschiedlichen Materialien
der Röhrchen zusammenhängen kann. Einige Differenzen waren auch klinisch
bedeutsam, da sie das Risiko einer diagnostischen Fehlinterpretation des
Laborbefundes in sich bergen. In einem weiteren Versuch wurden Vacutainer® mit
Trenngel verwendet, die unterschiedlichen Transportbedingungen bezüglich
Temperatur, Transportdauer und Zentrifugationsstatus ausgesetzt wurden. Es
zeigte sich, dass das Zentrifugieren der Blutproben auf die Stabilität der
meisten Parameter einen größeren Einfluss hatte als die Temperatur. Eine kurze
Transportdauer wirkte sich zusätzlich besser auf die Analyseresultate aus als
eine längere, da auch im Serum weiterhin metabolische Prozesse ablaufen. Diese
Prozesse sind jedoch geringgradiger als im Vollblut. Bei dieser Untersuchung
wurden auch NaF/KOx-Röhrchen zur Glukose-Bestimmung mitgeführt. Es zeigte
sich, dass der Glukosegehalt im Plasma der unzentrifugierten NaF/KOx-Röhrchen
stärker variierte als in den zentrifugierten Serum-Röhrchen. Zusätzlich war
der Glukosegehalt im Plasma signifikant niedriger als im Serum. Aus den
Ergebnissen dieser Untersuchungen ergaben sich die Empfehlungen, \-
Referenzbereiche zusammen mit dem verwendeten Blutentnahmesystem anzugeben, \-
Serum vor dem Transport der Blutproben abzuzentrifugieren, \- auf die
Bestimmung einiger Parameter zu verzichten, wenn eine längere Transportdauer
nicht vermieden werden kann und \- Serum-Röhrchen für die Bestimmung des
Glukosegehaltes zu verwenden, wenn eine Zentrifuge verfügbar ist. Diese Arbeit
hat gezeigt, dass die Präanalytik einen erheblichen Einfluss auf die
Stabilität der Parameter in Rinderblutproben ausüben kann. Eine
Standardisierung dieses Teilbereiches im Gesamtprozess der Analyse einer
Blutprobe ist daher notwendig, um diagnostisch verwertbare Analyseresultate zu
erhalten. Demzufolge sollten weitergehende Untersuchungen zu Wechselwirkungen
zwischen Röhrchenmaterial und Serum durchgeführt, eine standardisierte Vorgabe
zur Zentrifugationsmethodik von Rinderblutproben entwickelt und eigenständige
Referenzbereiche für Glukose im Serum und Plasma festgelegt werden.
de
dc.description.abstract
Blood examination in cattle can be an important factor regarding the health
status of single animals or of the herd. In the last few years, analytic
methods have been refined and quality management was introduced in laboratory
procedures. Thus, analytical errors could be reduced significantly. The
objective of this study was to create the general framework for dealing with
blood samples ex vivo and to provide guidelines for the quality assurance in
cattle practice. To this end, the influence of different systems for blood
sampling and transport conditions were examined with regard to serum
concentrations of selected metabolic parameters. Open and closed serum
monovettes® and vacutainers® with or without separator gel were used for the
comparisons of different systems for blood sampling. Statistically significant
differences were found for certain parameters, which could be related to the
different materials from which the blood tubes were made. Certain differences
were of clinical importance, since they bear the risks of diagnostic
misinterpretations of laboratory results. In order to examine the relevance of
different transport conditions, vacutainers® containing separator gel were
transported at different temperatures, for differing periods of time and were
either centrifugated or not. Apparently, centrifugation of blood samples was
more important than temperature regarding the stability of most parameters.
Short-term transportation caused more accurate results of blood analyses than
if the samples had been transported for a longer period of time, since certain
metabolic processes continue within the serum. However, activity of metabolic
processes is less than in whole blood samples. Examination of NaF/KOx tubes
for determination of glucose showed a greater variety in uncentrifugated
plasma samples than in centrifuged serum samples. Moreover, glucose
concentrations were significantly lower in the plasma than in the serum.
Recommendations based on the results of this study are: \- citation of
reference ranges according to the blood sampling system used; \-
centrifugation of serum prior to the transport of the blood samples; \-
certain parameters should not be examined in cases of long periods of
transportation; \- serum tubes should be used for determination of glucose if
a centrifuge is available. This study shows that preanalysis can be an
important factor for the stability of parameters in bovine blood samples.
Thus, standardisation of this process is necessary to obtain diagnostic
reliable results when analysing blood samples. Accordingly, further studies on
the interaction of serum and the material of blood tubes, standardised
prerequisites on the centrifugation methods of bovine blood samples and
individual reference ranges for glucose concentrations in serum as well as in
plasma are necessary.
en
dc.format.extent
IX, 203 S.
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject
blood chemistry
dc.subject
blood sampling
dc.subject
blood specimen collection
dc.subject
quality assurance
dc.subject
laboratory diagnosis
dc.subject
diagnostic techniques
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::630 Landwirtschaft
dc.title
Ex vivo-Veränderungen von Parametern des Stoffwechselprofils im Rinderblut
dc.contributor.firstReferee
Univ.-Prof. Dr. Kerstin E. Müller (Freie Universität Berlin)
dc.contributor.furtherReferee
Univ.-Prof. Dr. Helmut Hartmann(Freie Universität Berlin), Univ.-Prof. Dr.
Klaus Doll (Justus-Liebig-Universität Giessen)
dc.date.accepted
2009-07-14
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000012147-7
dc.title.subtitle
Ein Beitrag zur Entwicklung von Qualitä tsstandards fü r die Blutentnahme beim
Rind
dc.title.translated
Ex vivo-changes of metabolic profile parameters in bovine blood
en
dc.title.translatedsubtitle
A contribution to the development of quality standards for blood sampling in
cattle
en
refubium.affiliation
Veterinärmedizin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000012147
refubium.note.author
Gleichzeitig erschienen im DVG-Verl., Gießen, ISBN 978-3-94173-29-2
refubium.mycore.derivateId
FUDISS_derivate_000000006136
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access