dc.contributor.author
Dörfer, Stefan
dc.date.accessioned
2018-06-07T14:33:35Z
dc.date.available
2007-01-17T00:00:00.649Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/75
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-4279
dc.description
Gesamtdissertation
dc.description.abstract
Ziel dieser Arbeit war die Bestimmung der dreidimensionalen
Bracketübertragungsgenauigkeit des indirekten Klebens verschiedener
Schablonenmaterialien. Die Trays bestanden aus: Druckformfolien: 0,5 mm
Copyplast und 2,0 mm Biocryl. Die Schienen waren nicht getrennt und wurden
nacheinander übertragen. Silikon: Memosil. Die Schablonen wurden in 2 Hälften
getrennt. Diese wurden nacheinander übertragen. Silikone: Futar-D/Memosil. Die
Trays waren nicht segmentiert und wurden in einem Stück übertragen. Aus jedem
Material wurden 10 Trays hergestellt und je Übertragung wurden in der In-
vitro-Studie 7 Brackets auf ein Gipsmodell geklebt, welches als
Patientenersatz diente. Die Bracketpositionen wurden vor und nach der
Übertragung in 2 unterschiedlichen Raumebenen, die einen bekannten Winkel
zueinander bildeten, von einer konstanten Kameraposition optisch vermessen.
Für jeden Bracketpunkt wurde je Ebene ein Sagittalwert und ein Transversalwert
in einem zweidimensionalen Koordinatensystem bestimmt. Die vertikale
Bracketposition wurde aus den Koordinatenwerten der beiden Ebenen berechnet.
Folgende Ergebnisse wurden ermittelt: Die größte Bracketabweichung trat bei
allen 3 Materialien in der Vertikalen auf. Der durchschnittliche Fehler in der
Vertikalen zeigte bei allen 3 Methoden ähnliche Werte. In der Sagittalen
wurden für die Druckformfolien signifikant höhere Fehler festgestellt. Der
Fehler nahm nach posterior zu. Die Druckformfolien zeigten bei der Abweichung
benachbarter Brackets in jeder Raumdimension die signifikant höchsten
Abweichungen. Die Brackets kippten und drehten bei der Übertragung stärker als
bei den Silikontrays. Zwischen den Silikontrays bestand kein signifikanter
Unterschied. Jedoch zeigte der Ort der Segmentierung bei den Memosiltrays
einen erhöhten Übertragungsfehler in der Sagittalen und Vertikalen. In dieser
Arbeit wurde der Übertragungsfehler verschiedener Materialien des indirekten
Klebens ermittelt. Für eine Beurteilung des Gesamtfehlers des indirekten
Klebens muss der Bracketplatzierungsfehler auf den Ausgangsmodellen zusätzlich
berücksichtigt werden.
de
dc.description.abstract
The aim of this research is the definition of the exactness of the 3-D
bracket-transfer, using indirect bonding of different pattern-materials. The
trays consist of: Thermoplastic foils: 0,5 mm Copyplast and 2,0 mm Biocryl.
The trays had not been divided and they were transferred one after the other.
Silicone: Memosil. The tray was divided into two halves which were transferred
one after the other. Silicone: Futar-D/Memosil. The trays had not been
segmented and were transferred as a whole. Ten trays were made from each
material. In the in-vitro-study at every transfer seven of the brackets were
bonded on a cast which replaced the patient. Before and after the transfer the
positions of the brackets were optically measured from a steady camera
position at two different levels which formed a known correlating angle. For
each bracket position and each level one sagittal data and one transversal
data were determined in a 2-D coordinate system. The vertical bracket position
was calculated from the coordinates of both levels. The following results had
been ascertained: The maximum bracket difference occurred with all three
materials in a vertical levels. The average mistake in the vertical level
presented similar results in all three methods. At the sagittal level bigger
mistakes had significantly been ascertained at the thermoplastic trays. The
mistake was posteriorly rising. The difference of adjacent brackets in each
level showed the most significant and largest mistakes in the thermoplastic
trays. At transfer the brackets were tilting and turning more heavily as they
did at the silicone trays. There was no significant difference between the
silicone trays. The place of segmentation, however, showed an increasing
mistake of transfer in the sagittal and vertical level at the Memosil trays.
In this research the mistake of transfer of indirect bonding with different
materials had been ascertained. To judge about the mistake of indirect bonding
as a whole, the mistakes in placing the brackets at the original model need
additional consideration.
en
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject
indirekte Adhäsivtechnik
dc.subject
Übertragungsgenauigkeit
dc.subject
Multibracketapparatur
dc.subject
Druckformfolien
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Untersuchung der Übertragungsgenauigkeit verschiedener Methoden des indirekten
Klebens
dc.contributor.firstReferee
Prof. Dr. P.-G. Jost-Brinkmann
dc.contributor.furtherReferee
Prof. Dr. P. Schopf
dc.contributor.furtherReferee
Prof. Dr. R. Radlanski
dc.date.accepted
2007-03-23
dc.date.embargoEnd
2007-01-12
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000002797-9
dc.title.subtitle
\- Eine In-vitro-Studie -
dc.title.translated
Transfer accurary of bracket placement with indirect bonding techniques
en
dc.title.translatedsubtitle
\- in-vitro-study -
en
refubium.affiliation
Charité - Universitätsmedizin Berlin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000002797
refubium.mycore.transfer
http://www.diss.fu-berlin.de/2007/31/
refubium.mycore.derivateId
FUDISS_derivate_000000002797
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access