dc.contributor.author
Stüttgen, Ulrike
dc.date.accessioned
2018-06-07T20:17:17Z
dc.date.available
2011-01-24T10:58:34.678Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/6723
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-10922
dc.description.abstract
Die Zielsetzung der vorliegenden Untersuchungen war es, den Einfluss
unterschiedlicher Lagerungsbedingungen auf den Haftverbund zwischen Titan und
Verblendkeramik zu untersuchen, wobei die jeweilige Verblendkeramik mit Bonder
und ohne Bonder untersucht wurde. Untersucht wurde die Vita Titankeramik (Fa.
Vita) und die Triceram Titankeramik (Fa. Esprident). Die Titanprobenkörper der
Größe 25 x 3 x 0,5 mm wurden eigenhändig, wie in Kapitel 3.3 beschrieben, im
Labor Ticost Brandenburg hergestellt. Anschließend wurden je 7 Probenkörper
innerhalb einer Lagerungsart mit Triceram mit Bonder, Triceram ohne Bonder,
Vita mit Bonder und Vita ohne Bonder wie in Kapitel 3.5 beschrieben
beschichtet. Es wurden 28 Versuchsserien durchgeführt. In jeder Versuchsserie
wurden 7 Probenkörper getestet. 28 Probenkörper wurden trocken gelagert, 28
Probenkörper wurden eine Woche nass gelagert, 28 Probenkörper wurden ein Monat
nass gelagert, 28 Probenkörper wurden sechs Monate nass gelagert, 28
Probenkörper wurden eine Woche in künstlichem Speichel gelagert, 28
Probenkörper wurden ein Monat in künstlichem Speichel gelagert, 28
Probenkörper wurden sechs Monate in künstlichem Speichel gelagert. Nach
genauer Prüfung der Abmessung jedes einzelnen Prüfkörpers wurden die
Verbundfestigkeit zwischen Metall und Keramik mittels des Dreipunkt
Biegeversuchs nach SCHWICKERATH in einer Universal-Prüfmaschine der Firma
Zwick getestet. Die ermittelten Werte wurden kontinuierlich in einem Kraft-
Wege-Diagramm aufgezeichnet. Beim Vergleich der unterschiedlichen
Lagerungsbedingungen konnte bei Triceram mit Bonder lediglich bei der
sechsmonatigen Nasslagerung ein signifikant höheres Ergebnis gegenüber der
sechsmonatigen Speichellagerung erzielt werden. Verzichtet man jedoch auf
einen Bonderauftrag, so ergeben sich zahlreiche signifikant unterschiedliche
Ergebnisse, wobei festgestellt werden kann dass die Verbundfestigkeit meist
mit der Dauer der Lagerung abnimmt. Ähnliche Ergebnisse liefert die
Titankeramik Vita. Hier können bei der Verbundfestigkeitsprüfung für Vita mit
Bonder keine signifikant unterschiedlichen Ergebnisse festgestellt werden.
Wird jedoch auf einen Bonderauftrag verzichtet, so ergeben sich auch hier
signifikant geringere Ergebnisse. Bei der keramischen Verblendung von Titan
kann auf das Aufbringen eines Bonder keinesfalls verzichtet werden. Wenn
gleich die Ergebnisse bei Trockenlagerung und kurzzeitiger Nasslagerung noch
kaum signifikant unterschiedliche Ergebnisse liefern, so zeigen doch die
Untersuchungen bei längerer Lagerung in feuchtem Milieu, dass hier ein
Bonderauftrag zu weitaus stabileren Verbundfestigkeitswerten führen kann. Im
Hinblick darauf, dass eine keramisch verblendete Restauration dauerhaft einem
solchen Milieu ausgesetzt ist, darf auf den Auftrag eines Bonder nicht
verzichtet werden.
de
dc.description.abstract
Aim of the present study was an investigation of the influence of different
storage conditions on the bond strength between cp-titanium and two veneering
porcelains. Both porcelain compound systems were investigated with and without
the use of porcelain bonder. The porcelains under investigation were Vita
Titankeramik (Vita) and Triceram (Esprident). The titanium test specimens of I
defined size of 25 mm x 3 mm x 0,5 mm were individually manufactured at the
dental laboratory Ticost (Brandenburg) as described in detail in chapter 3.3.
<<in the following, seven test specimens each were stored under different
conditions: Triceram with porcelain bonder, Vita Titankeramik without
porcelain bonder, all having been veneered as described in detail in chapter
3.5. 28 test series were conducted with 7 test specimens of the four different
types each under the following conditions: 28 test specimens were stored under
dry conditions. 28 test specimens were stored under wet conditions simulated
by water for on week. 28 test specimens were stored under wet conditions
simulated by water for one month. 28 test specimens were stored under wet
conditions simulated by water for six month. 28 test specimens were stored
under wet conditions simulated by artificial saliva for one week. 28 test
specimens were stored under wet conditions simulated by artificial saliva for
one month. 28 test specimens were stored under wet conditions simulated by
artificial saliva for six months. The resulting bond strength was evaluated
and their effects significantly higher bond strength could only be found for
Triceram with bonder stored under wet conditions simulated by water for six
months as compared to Triceram with bonder stored under wet conditions
simulated by artificial saliva for six months. When no bonder is used a range
of significant differences can be found: It can be stated that bond strengths
decrease with the duration of storage. Similar results were found for Vita
Titankeramik. With the use of bonder no significant differences in bond
strength can be found. But again, if no bonder is used bond strength values
decrease significantly over time. With porcelain veneered titanium a bonder
should definitely be used and is indispensable. Even after short storage
durations results do not differ significantly between dry storage conditions
and wet storage conditions. The investigations show that with longer duration
of storage under wet conditions bond strength will profit from the use of a
bonder. With respect to the fact that a porcelain veneered dental restoration
will exposed to wet conditions continually, use of a bonder is a must.
en
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject
veneering porcelain
dc.subject
different conditions
dc.subject
Vita Titankeramik
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit
dc.title
Untersuchung zur lagerbedingten Änderung des Haftverbundes zwischen Titan und
verschiedenen Keramiken mit und ohne Bonder
dc.contributor.firstReferee
Priv.-Doz. Dr. R. Strietzel
dc.contributor.furtherReferee
Priv.-Doz. Dr. rer. nat. W.-D. Müller
dc.contributor.furtherReferee
Prof. Dr. J. M. Setz
dc.date.accepted
2011-01-07
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000020359-0
dc.title.translated
Investigation of the influence of different storage conditions on the bond
strength between titanium and different porcelains with and without the use of
porcelain bonder
en
refubium.affiliation
Charité - Universitätsmedizin Berlin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000020359
refubium.mycore.derivateId
FUDISS_derivate_000000008716
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access