dc.contributor.author
Schirmer, Olaf
dc.date.accessioned
2018-06-07T17:57:05Z
dc.date.available
2007-08-13T00:00:00.649Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/4460
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-8660
dc.description
Titelblatt und Inhaltsverzeichnis
Einleitung
Ziel der Arbeit
Material und Methode
Ergebnisse
Diskussion
Bildanhang und Fallbeispiele
Zusammenfassung
Literaturquellen
dc.description.abstract
In dieser Arbeit wurden 127 Patienten mit pertrochantären Femurfrakturen, die
von August 2001 bis zum Februar 2005 in der unfallchirurgischen Abteilung des
Krankenhaus Flemmingstraße der Klinikum Chemnitz gGmbH mit einem TriGen-
Trochanternagel der Fa. Smith-Nephew osteosynthetisch versorgt wurden,
ausgewertet. Das Durchscnittsalter der Patienten betrug dabei 81,2 Jahre. Bei
einer nahezu gleichmäßigen Seitenverteilung fanden sich in 18,1%
A-1-Frakturen, in 77,2% A-2-Frakturen und in 4,7% A-3-Frakturen. Häufigste
Unfallursachen waren Stürze auf der Ebene im Sinne von low-energy-Traumata mit
96,9%. High-energy-Traumata, wie sie bei Stürzen aus größerer Höhe und
Verkehrsunfällen vorkommen, traten in insgesamt 3,1% der Fälle auf. Die
operative Versorgung erfolgte bei 53,5% der Patienten innerhalb von 24
Stunden, bis 48 Stunden wurden weitere 26 % operiert. Bei 11,8% der Patienten
mußte länger als 48 Stunden bis zur Versorgung gewartet werden. 8,7% der
Verunfallten konnten erst zu einem weit späteren Zeitpunkt operiert werden.
Die Osteosynthese erfolgte mit dem TriGen-Trochanternagel, der in zwei Größen
zur Verfügung steht. Dabei wurde der 10 x 150 mm - Nagel in 91,3% der Fälle
und der 11,5 x 150 mm Nagel in 8,7 % der Fälle verwendet. In 96,9 % wurde
die operative Versorgung in einer Allgemeinnarkose und nur in 3,1% in einer
Spinalanästhesie durchgeführt. 34,65 % der Patienten entwickelten während des
stationären Aufenthaltes eine allgemeine Komplikation, wobei dieser Wert im
Rahmen der in anderen Studien veröffentlichten Ergebnisse liegt. Die lokale
Komplikationsrate lag bei 6,3 %. Dabei wurden Hämatome und Wundinfektionen als
nicht direkt implantatabhängige Komplikationen mitfasst sowie
Implantatdislokationen und distale Fehlverriegelungen als implantatabhängige
Komplikationen. Im Vergleich zu den Standardimplantaten Gammanagel der Fa.
Stryker-Howmedica und dem proximalen Femurnagel der Fa. Synthes / Clinical
House ließen sich dabei, bezogen auf die direkt implantatbezogenen
Komplikationen günstigere Ergebnisse bei insgesamt gutem Handling des
Implantates erreichen.
de
dc.description.abstract
In this publication 127 patients with petrochanteric fractures were analysed,
who were treated by an osteosynthesis with a TriGen Trochanteric Nail made by
Smith-Nephew at the surgical emergency department at Krankenhaus
Flemmingstrasse, Klinikum Chemnitz gGbmH from August 2001 until February 2005.
The average patient age was 81.2 years. At an even distribution of the body
side 18.1% of the cases were A-1 fractures, 77.2% A-2 fractures and 4.7% A-3
fractures. The most common accidents at 96.9% were falls at on an even level
caused by low-energy-Traumata. High-energy-Traumata, caused by falls from a
greater height and at road traffic accidents appeared at 3.1% of the cases.
Surgical treatment was carried out at 53.5% of the patients within 24 hours,
within 48 hours a further 26% were operated. At 11.8% of the patients it was
necessary to wait longer than 48 hours until treatment could be carried out.
8.7% of the patients could only be operated at a much later point. The
osteosynthesis was made with a TriGen Trochanteric Nail, which is available in
two sizes. A nail size of 10 x 150 mm was used in 91.3% of the cases and in
8.7% a nail size of 11.5 x 150 mm was used. 96.9% were treated under a general
anaesthesia and in only 3.1% of the cases a spinal anaesthesia was used.
34.65% of the patients developed general complications during their in-patient
treatment, this figure is within the results published in other studies. The
local complications rate was at 6.3%. Haematomas and wound infections were
considered as indirect implant dependent complications and implant
dislocations and malpositioning of the distal locking screw as implant
dependent complications. In comparison to the standard implantats Trochanteric
Gamma Nail made by Stryker-Howmedica and the Proximal Femoral Nail made by
Synthes / Clinical House good results were achieved relating to the implantat
dependent complications with a good handling of the implant
en
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject
pertrochanteric fractures
dc.subject
Trigen-Trochanteric-Nail
dc.subject
osteosynthesis
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Die Frühergebnisse der Versorgung pertrochantärer Femurfrakturen mit dem
TriGen-Trochanternagel
dc.contributor.firstReferee
Prof. Dr. med. J. Boese-Landgraf
dc.contributor.furtherReferee
Priv.-Doz. Dr. med. H-.H. Schauwecker
dc.contributor.furtherReferee
Prof. Dr. med. C. Josten
dc.date.accepted
2007-09-23
dc.date.embargoEnd
2007-01-12
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000003066-7
dc.title.translated
The early results of the osteosynthesis of pertrochanteric fractures with the
TriGen-Trochanteric-Nail
en
refubium.affiliation
Charité - Universitätsmedizin Berlin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000003066
refubium.mycore.transfer
http://www.diss.fu-berlin.de/2007/562/
refubium.mycore.derivateId
FUDISS_derivate_000000003066
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access