dc.contributor.author
Fritsche-Guenther, Raphaela
dc.contributor.author
Gloaguen, Yoann
dc.contributor.author
Eisenberger, Alina
dc.contributor.author
Kirwan, Jennifer A.
dc.date.accessioned
2024-03-01T16:14:49Z
dc.date.available
2024-03-01T16:14:49Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/42610
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-42334
dc.description.abstract
The AbsoluteIDQ p400 HR kit is a commercial product for targeted metabolomics. While the kit has been validated for human plasma and serum, adherent cell lysates have not yet been evaluated. We have optimized the detection of polar and lipid metabolites in cell lysates using the kit to enable robust and repeatable analysis of the detected metabolites. Parameters optimized include total cell mass, loading volume and extraction solvent. We present a cell preparation and analytical method and report on the performance of the kit with regard to detectability of the targeted metabolites and their repeatability. The kit can be successfully used for a relative quantification analysis of cell lysates from adherent cells although validated only for human plasma and serum. Most metabolites are below the limit of the Biocrates' set quantification limits and we confirmed that this relative quantification can be used for further statistical analysis. Using this approach, up to 45% of the total metabolites in the kit can be detected with a reasonable analytical performance (lowest median RSD 9% and 13% for LC and FIA, respectively) dependent on the method used. We recommend using ethanol as the extraction solvent for cell lysates of osteosarcoma cell lines for the broadest metabolite coverage and 25 mg of cell mass with a loading volume of 20 mu L per sample.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
AbsoluteIDQ p400 HR kit
en
dc.subject
metabolomics
en
dc.subject
adherent cell lysates
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Analysis of adherent cell culture lysates with low metabolite concentrations using the Biocrates AbsoluteIDQ p400 HR kit
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
7933
dcterms.bibliographicCitation.doi
10.1038/s41598-022-11118-7
dcterms.bibliographicCitation.journaltitle
Scientific Reports
dcterms.bibliographicCitation.number
1
dcterms.bibliographicCitation.originalpublishername
Springer Nature
dcterms.bibliographicCitation.volume
12
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
Springer Nature DEAL
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
35562573
dcterms.isPartOf.eissn
2045-2322