dc.contributor.author
Melzow, Florentina
dc.contributor.author
Mertens, Sarah
dc.contributor.author
Todorov, Hristo
dc.contributor.author
Groneberg, David A.
dc.contributor.author
Paris, Sebastian
dc.contributor.author
Gerber, Alexander
dc.date.accessioned
2023-11-30T16:45:03Z
dc.date.available
2023-11-30T16:45:03Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/41675
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-41395
dc.description.abstract
Background: Due to exposure to potentially infectious aerosols during treatments, the dental personnel is considered being at high risk for aerosol transmitted diseases like COVID-19. The aim of this study was to evaluate aerosol exposure during different dental treatments as well as the efficacy of dental suction to reduce aerosol spreading.
Methods: Dental powder-jet (PJ; Air-Flow (R)), a water-cooled dental handpiece with a diamond bur (HP) and water-cooled ultrasonic scaling (US) were used in a simulation head, mounted on a dental unit in various treatment settings. The influence of the use of a small saliva ejector (SE) and high-volume suction (HVS) was evaluated. As a proxy of aerosols, air-born particles (PM10) were detected using a Laser Spectrometer in 30 cm distance from the mouth. As control, background particle counts (BC) were measured before and after experiments.
Results: With only SE, integrated aerosol levels [median (Q25/Q75) mu g/m(3) s] for PJ [91,246 (58,213/118,386) mu g/m(3) s, p < 0.001, ANOVA] were significantly increased compared to BC [7243 (6501/8407) mu g/m(3) s], whilst HP [11,119 (7190/17,234) mu g/m(3) s, p > 0.05] and US [6558 (6002/7066) mu g/m(3) s; p > 0.05] did not increase aerosol levels significantly. The use of HVS significantly decreased aerosol exposure for PJ [37,170 (29,634/51,719) mu g/m(3) s; p < 0.01] and HP [5476 (5066/5638) mu g/m(3) s; p < 0.001] compared to SE only, even reaching lower particle counts than BC levels for HP usage (p < 0.001).
Conclusions: To reduce the exposure to potentially infectious aerosols, HVS should be used during aerosol-forming dental treatments.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Oral medicine
en
dc.subject
Dental staff
en
dc.subject
Dental suction
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Aerosol exposure of staff during dental treatments: a model study
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
128
dcterms.bibliographicCitation.doi
10.1186/s12903-022-02155-9
dcterms.bibliographicCitation.journaltitle
BMC Oral Health
dcterms.bibliographicCitation.number
1
dcterms.bibliographicCitation.originalpublishername
Springer Nature
dcterms.bibliographicCitation.volume
22
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
Springer Nature DEAL
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
35428223
dcterms.isPartOf.eissn
1472-6831