dc.contributor.author
Jänicke, Lena Katharina
dc.contributor.author
Preusker, Rene
dc.contributor.author
Celesti, Marco
dc.contributor.author
Tudoroiu, Marin
dc.contributor.author
Fischer, Jürgen
dc.contributor.author
Schüttemeyer, Dirk
dc.contributor.author
Drusch, Matthias
dc.date.accessioned
2023-08-10T12:46:24Z
dc.date.available
2023-08-10T12:46:24Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/40425
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-40146
dc.description.abstract
During the tandem phase of Sentinel-3A and Sentinel-3B in summer 2018 the Ocean and Land Colour Imager (OLCI) mounted on the Sentinel-3B satellite was reprogrammed to mimics ESA's eighth Earth Explorer, the FLuorescence EXplorer (FLEX). The OLCI in FLEX configuration (OLCI-FLEX) had 45 spectral bands between 500 and 792 nm. The new data set with high-spectral-resolution measurements (bandwidth: 1.7–3.7 nm) serves as preparation for the FLEX mission. Spatially co-registered measurements of both instruments are used for the atmospheric correction and the retrieval of surface parameters, e.g. the fluorescence or the leaf area index. For such combined products, it is essential that both instruments are radiometrically consistent. We developed a transfer function to compare radiance measurements from different optical sensors and to monitor their consistency.
In the presented study, the transfer function shifts information gained from high-resolution “FLEX-mode” settings to information convolved with the spectral response of the normal (lower) spectral resolution of the OLCI sensor. The resulting reconstructed low-resolution radiance is representative of the high-resolution data (OLCI-FLEX), and it can be compared with the measured low-resolution radiance (OLCI-A measurements). This difference is used to quantify systematic differences between the instruments. Applying the transfer function, we could show that OLCI-A is about 2 % brighter than OLCI-FLEX for most bands of the OLCI-FLEX spectral domain. At the longer wavelengths (> 770 nm) OLCI-A is about 5 % darker. Sensitivity studies showed that the parameters affecting the quality of the comparison of OLCI-A and OLCI-FLEX with the transfer function are mainly the surface reflectance and secondarily the aerosol composition. However, the aerosol composition can be simplified as long as it is treated consistently in all steps in the transfer function.
Generally, the transfer function enables direct comparison of instruments with different spectral responses even with different observation geometries or different levels of observation. The method is sensitive to measurement biases and errors resulting from the processing. One application could be the quality control of the FLEX mission; presently it is also useful for the quality control of the OLCI-FLEX data.
en
dc.format.extent
21 Seiten
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
OLCI-A/B tandem phase
en
dc.subject
FLuorescence EXplorer (FLEX)
en
dc.subject.ddc
500 Naturwissenschaften und Mathematik::550 Geowissenschaften, Geologie::551 Geologie, Hydrologie, Meteorologie
dc.title
OLCI-A/B tandem phase: evaluation of FLuorescence EXplorer (FLEX)-like radiances and estimation of systematic differences between OLCI-A and OLCI-FLEX
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.doi
10.5194/amt-16-3101-2023
dcterms.bibliographicCitation.issue
12
dcterms.bibliographicCitation.journaltitle
Atmospheric Measurement Techniques
dcterms.bibliographicCitation.originalpublishername
Copernicus Publications
dcterms.bibliographicCitation.pagestart
3101
dcterms.bibliographicCitation.pageend
3121
dcterms.bibliographicCitation.volume
2023/16
dcterms.bibliographicCitation.url
https://doi.org/10.5194/amt-16-3101-2023
refubium.affiliation
Geowissenschaften
refubium.affiliation.other
Institut für Meteorologie

refubium.note.author
Die Publikation ist aus Open Access Publikationsgeldern der Freien Universität Berlin gefördert.
de
refubium.note.author
We acknowledge support by the Open Access Publication Initiative of the Freie Universität Berlin.
en
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.isPartOf.eissn
1867-8548