dc.contributor.author
Leopold, Vincent Justus
dc.contributor.author
Conrad, Juana
dc.contributor.author
Zahn, Robert Karl
dc.contributor.author
Hipfl, Christian
dc.contributor.author
Perka, Carsten
dc.contributor.author
Hardt, Sebastian
dc.date.accessioned
2023-07-12T12:06:20Z
dc.date.available
2023-07-12T12:06:20Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/40062
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-39784
dc.description.abstract
Aims: The aim of this study was to compare the fixation stability and complications in patients undergoing periacetabular osteotomy (PAO) with either K-wire or screw fixation.
Patients and methods: We performed a retrospective study to analyze a consecutive series of patients who underwent PAO with either screw or K-wire fixation. Patients who were treated for acetabular retroversion or had previous surgery on the ipsilateral hip joint were excluded. 172 patients (191 hips: 99 K-wire/92 screw fixation) were included. The mean age at the time of PAO was 29.3 years (16-48) in the K-wire group and 27.3 (15-45) in the screw group and 83.9% were female. Clinical parameters including duration of surgery, minor complications (soft tissue irritation and implant migration) and major complications (implant failure and non-union) were evaluated. Radiological parameters including LCE, TA and FHEI were measured preoperatively, postoperatively and at 3-months follow-up.
Results: Duration of surgery was significantly reduced in the K-wire group with 88.2 min (53-202) compared to the screw group with 119.7 min (50-261) (p < 0.001). Soft tissue irritation occurred significantly more often in the K-wire group (72/99) than in the screw group (36/92) (p < 0.001). No group showed significantly more implant migration than the other. No major complications were observed in either group. Postoperative LCE, TA and FHEI were improved significantly in both groups for all parameters (p = < 0.0001). There was no significant difference for initial or final correction for the respective parameters between the two groups. Furthermore, no significant difference in loss of correction was observed between the two groups for the respective parameters.
Conclusion: K-wire fixation is a viable and safe option for fragment fixation in PAO with similar stability and complication rates as screw fixation. An advantage of the method is the significantly reduced operative time. A disadvantage is the significantly higher rate of implant-associated soft tissue irritation, necessitating implant removal.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Developmental dysplasia of the hip
en
dc.subject
Periacetabular osteotomy
en
dc.subject
Surgical technique
en
dc.subject
Fixation options
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Fixation stability and implant-associated complications in periacetabular osteotomy: a comparison of screw and K-wire fixation
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.doi
10.1007/s00402-021-04112-7
dcterms.bibliographicCitation.journaltitle
Archives of Orthopaedic and Trauma Surgery
dcterms.bibliographicCitation.number
2
dcterms.bibliographicCitation.originalpublishername
Springer Nature
dcterms.bibliographicCitation.pagestart
691
dcterms.bibliographicCitation.pageend
697
dcterms.bibliographicCitation.volume
143
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
Springer Nature DEAL
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
34406508
dcterms.isPartOf.eissn
1434-3916