dc.contributor.author
Kottwitz, Jan
dc.contributor.author
Bruno, Katelyn A.
dc.contributor.author
Berg, Jan
dc.contributor.author
Salomon, Gary R.
dc.contributor.author
Fairweather, DeLisa
dc.contributor.author
Elhassan, Mawahib
dc.contributor.author
Baltensperger, Nora
dc.contributor.author
Kissel, Christine K.
dc.contributor.author
Lovrinovic, Marina
dc.contributor.author
Baltensweiler, Andrea
dc.contributor.author
Schmied, Christian
dc.contributor.author
Templin, Christian
dc.contributor.author
Lima, Joao A.C.
dc.contributor.author
Landmesser, Ulf
dc.contributor.author
Lüscher, Thomas F.
dc.contributor.author
Manka, Robert
dc.contributor.author
Heidecker, Bettina
dc.date.accessioned
2022-11-09T12:35:32Z
dc.date.available
2022-11-09T12:35:32Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/36770
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-36483
dc.description.abstract
There is an unmet need for accurate and practical screening to detect myocarditis. We sought to test the hypothesis that the extent of acute myocarditis, measured by late gadolinium enhancement (LGE) on cardiac magnetic resonance imaging (CMR), can be estimated based on routine blood markers. A total of 44 patients were diagnosed with acute myocarditis and included in this study. There was strong correlation between myoglobin and LGE (rs = 0.73 [95% CI 0.51; 0.87], p < 0.001), while correlation was weak between LGE and TnT-hs (rs = 0.37 [95% CI 0.09; 0.61], p = 0.01). Receiver operating curve (ROC) analysis determined myoglobin ≥ 87 μg/L as cutoff to identify myocarditis (92% sensitivity, 80% specificity). The data were reproduced in an established model of coxsackievirus B3 myocarditis in mice (n = 26). These data suggest that myoglobin is an accurate marker of acute myocarditis. Graphical Abstract Receiver operating curve analysis determined myoglobin ≥ 87 μg/L as cutoff to identify myocarditis and these data were reproduced in an established model of coxsackievirus B3 myocarditis in mice: CMRI, cardiac magnetic resonance imaging; Mb, myoglobin; LGE, late gadolinium enhancement; ROC, receiver operating curve analysis.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Cardiac enzymes
en
dc.subject
Late gadolinium enhancement
en
dc.subject
Magnetic resonance imaging
en
dc.subject
Myocardial inflammation
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Myoglobin for Detection of High-Risk Patients with Acute Myocarditis
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.doi
10.1007/s12265-020-09957-8
dcterms.bibliographicCitation.journaltitle
Journal of Cardiovascular Translational Research
dcterms.bibliographicCitation.number
5
dcterms.bibliographicCitation.originalpublishername
Springer Nature
dcterms.bibliographicCitation.pagestart
853
dcterms.bibliographicCitation.pageend
863
dcterms.bibliographicCitation.volume
13
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
Springer Nature DEAL
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
32006209
dcterms.isPartOf.issn
1937-5387
dcterms.isPartOf.eissn
1937-5395