dc.contributor.author
Zhao, Jing
dc.contributor.author
Hamm, Bernd
dc.contributor.author
Brenner, Winfried
dc.contributor.author
Makowski, Marcus R.
dc.date.accessioned
2022-06-21T11:01:32Z
dc.date.available
2022-06-21T11:01:32Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/35354
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-35070
dc.description.abstract
Purpose: This study aimed to calculate an applicable relative ratio threshold value instead of the absolute threshold value for simultaneous 68Ga prostate-specific membrane antigen/positron emission tomography ([68Ga]Ga-PSMA-11 PET) in patients with prostate cancer (PCa).
Materials and methods: Our study evaluated thirty-two patients and 170 focal prostate lesions. Lesions are classified into groups according to Prostate Imaging Reporting and Data System (PI-RADS). Standardized uptake values maximum (SUVmax), corresponding lesion-to-background ratios (LBRs) of SUVmax, and LBR distributions of each group were measured based on regions of interest (ROI). We examined LBR with receiver operating characteristic analysis to determine threshold values for differentiation between multiparametric magnetic resonance imaging (mpMRI)-positive and mpMRI-negative lesions.
Results: We analyzed a total of 170 focal prostate lesions. Lesions number of PI-RADS 2 to 5 was 70, 16, 46, and 38. LBR of SUVmax of each PI-RADS scores was 1.5 (0.9, 2.4), 2.5 (1.6, 3.4), 3.7 (2.6, 4.8), and 6.7 (3.5, 12.7). Based on an optimal threshold ratio of 2.5 to be exceeded, lesions could be classified into MRI-positive lesion on [68Ga]Ga-PSMA PET with a sensitivity of 85.2%, a specificity of 72.0%, with the corresponding area under the receiver operating characteristic curve (AUC) of 0.83, p < 0.001. This value matches the imaging findings better.
Conclusion:
The ratio threshold value of SUVmax, LBR, has improved clinical and research applicability compared with the absolute value of SUVmax. A higher threshold value than the background’s uptake can dovetail the imaging findings on MRI better. It reduces the bias from using absolute background uptake value as the threshold value.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Prostate cancer
en
dc.subject
Multiparametric MRI
en
dc.subject
[Ga-68]Ga-PSMA PET/MRI
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Lesion-to-background ratio threshold value of SUVmax of simultaneous [68Ga]Ga-PSMA-11 PET/MRI imaging in patients with prostate cancer
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
137
dcterms.bibliographicCitation.doi
10.1186/s13244-020-00926-y
dcterms.bibliographicCitation.journaltitle
Insights into Imaging
dcterms.bibliographicCitation.originalpublishername
Springer Nature
dcterms.bibliographicCitation.volume
11
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
Springer Nature DEAL
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
33331959
dcterms.isPartOf.eissn
1869-4101