dc.contributor.author
Rudolph, Madhuri Monique
dc.contributor.author
Baur, Alexander Daniel Jacques
dc.contributor.author
Cash, Hannes
dc.contributor.author
Haas, Matthias
dc.contributor.author
Mahjoub, Samy
dc.contributor.author
Hartenstein, Alexander
dc.contributor.author
Hamm, Charlie Alexander
dc.contributor.author
Beetz, Nick Lasse
dc.contributor.author
Konietschke, Frank
dc.contributor.author
Hamm, Bernd
dc.contributor.author
Asbach, Patrick
dc.contributor.author
Penzkofer, Tobias
dc.date.accessioned
2022-05-18T13:01:21Z
dc.date.available
2022-05-18T13:01:21Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/35046
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-34763
dc.description.abstract
The purpose of this study is to compare diagnostic performance of Prostate Imaging Reporting and Data System (PI-RADS) version (v) 2.1 and 2.0 for detection of Gleason Score (GS) ≥ 7 prostate cancer on MRI. Three experienced radiologists provided PI-RADS v2.0 scores and at least 12 months later v2.1 scores on lesions in 333 prostate MRI examinations acquired between 2012 and 2015. Diagnostic performance was assessed retrospectively by using MRI/transrectal ultrasound fusion biopsy and 10-core systematic biopsy as the reference. From a total of 359 lesions, GS ≥ 7 tumor was present in 135 lesions (37.60%). Area under the ROC curve (AUC) revealed slightly lower values for peripheral zone (PZ) and transition zone (TZ) scoring in v2.1, but these differences did not reach statistical significance. A significant number of score 2 lesions in the TZ were downgraded to score 1 in v2.1 showing 0% GS ≥ 7 tumor (0/11). The newly introduced diffusion-weighted imaging (DWI) upgrading rule in v2.1 was applied in 6 lesions from a total of 143 TZ lesions (4.2%). In summary, PI-RADS v2.1 showed no statistically significant differences in overall diagnostic performance of TZ and PZ scoring compared to v2.0. Downgraded BPH nodules showed favorable cancer frequencies. The new DWI upgrading rule for TZ lesions was applied in only few cases.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Area Under Curve
en
dc.subject
Diffusion Magnetic Resonance Imaging
en
dc.subject
Early Detection of Cancer
en
dc.subject
Image-Guided Biopsy
en
dc.subject
Neoplasm Grading
en
dc.subject
Prostatic Neoplasms
en
dc.subject
Radiographic Image Interpretation, Computer-Assisted
en
dc.subject
Retrospective Studies
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Diagnostic performance of PI-RADS version 2.1 compared to version 2.0 for detection of peripheral and transition zone prostate cancer
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
15982
dcterms.bibliographicCitation.doi
10.1038/s41598-020-72544-z
dcterms.bibliographicCitation.journaltitle
Scientific Reports
dcterms.bibliographicCitation.originalpublishername
Springer Nature
dcterms.bibliographicCitation.volume
10
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
Springer Nature DEAL
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
32994502
dcterms.isPartOf.eissn
2045-2322