dc.description.abstract
Background: To evaluate the influence of Selective Laser Trabeculoplasty (SLT) on iStent inject® outcomes in open-angle glaucoma (OAG).
Methods: In this retrospective comparative cohort outcome study, 66 patients who were treated with two iStent inject® devices were included. Patients were divided into two subgroups consisting of patients without SLT treatment prior to surgery and patients who had been treated previously with 360° SLT but without sufficient response. Outcome measures included intraocular pressure (IOP) and number of antiglaucoma medications after 6 weeks with three, six, 12, and 24 month follow-ups.
Results: Mean preoperative IOP decreased from 20.4 ± 5.3 mmHg to 14.8 ± 3.0 mmHg for patients without SLT treatment prior to surgery (p = 0.001) and from 19.2 ± 4.5 mmHg to 14.0 ± 1.6 mmHg for patients with insufficient response to 360° SLT treatment (p = 0.027) at 12 months after iStent inject® implantation. No significant difference was found between the two groups (p > 0.05). The number of antiglaucoma medications did not change in both groups (p > 0.05) and showed no significant difference between the two groups (p > 0.05).
Conclusion: Prior SLT treatment seems to have no negative influence on the IOP lowering-effect of iStent inject® implantation in patients with OAG. It is therefore an appropriate incremental procedure with no exclusion criterion for an iStent inject® implantation.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
iStent inject
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Influence of Selective Laser Trabeculoplasty (SLT) on the iStent inject® outcomes
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
457
dcterms.bibliographicCitation.doi
10.1186/s12886-020-01723-3
dcterms.bibliographicCitation.journaltitle
BMC Ophthalmology
dcterms.bibliographicCitation.originalpublishername
Springer Nature
dcterms.bibliographicCitation.volume
20
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
Springer Nature DEAL
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
33213403
dcterms.isPartOf.eissn
1471-2415