dc.contributor.author
Schulz, Marten
dc.contributor.author
Kleinjans, Moritz
dc.contributor.author
Strnad, Pavel
dc.contributor.author
Demir, Münevver
dc.contributor.author
Holtmann, Theresa M.
dc.contributor.author
Tacke, Frank
dc.contributor.author
Wree, Alexander
dc.date.accessioned
2021-08-31T13:28:04Z
dc.date.available
2021-08-31T13:28:04Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/31772
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-31504
dc.description.abstract
Liver affection of Alpha1-antitrypsin deficiency (AATD) can lead to cirrhosis and hepatocellular carcinoma (HCC). A noninvasive severity assessment of liver disease in AATD is urgently needed since laboratory parameters may not accurately reflect the extent of liver involvement. Preliminary data exist on two-dimensional shear wave elastography (2D-SWE) being a suitable method for liver fibrosis measurement in AATD. AATD patients without HCC were examined using 2D-SWE, shear wave dispersion imaging (SWD) and transient elastography (TE). Furthermore, liver steatosis was assessed using the controlled attenuation parameter (CAP) and compared to the new method of attenuation imaging (ATI). 29 AATD patients were enrolled, of which 18 had the PiZZ genotype, eight had PiMZ, two had PiSZ and one had a PiZP-Lowell genotype. 2D-SWE (median 1.42 m/S, range 1.14-1.83 m/S) and TE (median 4.8 kPa, range 2.8-24.6 kPa) values displayed a significant correlation (R = 0.475, p < 0.05). 2D-SWE, ATI (median 0.56 dB/cm/MHz, range 0.43-0.96 dB/cm/MHz) and CAP (median 249.5 dB/m, range 156-347 dB/m) values were higher in PiZZ when compared to other AATD genotypes. This study provides evidence that 2D-SWE is a suitable method for the assessment of liver disease in AATD. The newer methods of SWD and ATI require further evaluation in the context of AATD.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
alpha1-antitrypsin deficiency (AATD)
en
dc.subject
shear wave elastography (SWE)
en
dc.subject
shear wave dispersion (SWD)
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Shear Wave Elastography and Shear Wave Dispersion Imaging in the Assessment of Liver Disease in Alpha1-Antitrypsin Deficiency
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
629
dcterms.bibliographicCitation.doi
10.3390/diagnostics11040629
dcterms.bibliographicCitation.journaltitle
Diagnostics
dcterms.bibliographicCitation.number
4
dcterms.bibliographicCitation.originalpublishername
MDPI AG
dcterms.bibliographicCitation.volume
11
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
33807358
dcterms.isPartOf.eissn
2075-4418