dc.contributor.author
Wagner, Franziska C.
dc.contributor.author
Reese, Sven
dc.contributor.author
Gerlach, Kerstin
dc.contributor.author
Böttcher, Peter
dc.contributor.author
Mülling, Christoph K. W.
dc.date.accessioned
2021-08-17T07:59:29Z
dc.date.available
2021-08-17T07:59:29Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/31650
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-31380
dc.description.abstract
Background
Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min.
Results
A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance.
Conclusion
In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs.
en
dc.format.extent
15 Seiten
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Superficial digital flexor tendon (SDFT)
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::630 Landwirtschaft::630 Landwirtschaft und verwandte Bereiche
dc.title
Cyclic tensile tests of Shetland pony superficial digital flexor tendons (SDFTs) with an optimized cryo-clamp combined with biplanar high-speed fluoroscopy
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
223
dcterms.bibliographicCitation.doi
10.1186/s12917-021-02914-w
dcterms.bibliographicCitation.journaltitle
BMC Veterinary Research
dcterms.bibliographicCitation.number
1
dcterms.bibliographicCitation.volume
17
dcterms.bibliographicCitation.url
https://doi.org/10.1186/s12917-021-02914-w
refubium.affiliation
Veterinärmedizin
refubium.affiliation.other
Klinik für Kleine Haustiere
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.isPartOf.eissn
1746-6148
refubium.resourceType.provider
WoS-Alert