dc.contributor.author
Bressem, Keno K.
dc.contributor.author
Vahldiek, Janis L.
dc.contributor.author
Erxleben, Christoph
dc.contributor.author
Poch, Franz
dc.contributor.author
Shnaiyen, Seyd
dc.contributor.author
Geyer, Beatrice
dc.contributor.author
Lehmann, Kai S.
dc.contributor.author
Hamm, Bernd
dc.contributor.author
Niehues, Stefan M.
dc.date.accessioned
2020-02-07T13:25:07Z
dc.date.available
2020-02-07T13:25:07Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/26621
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-26378
dc.description.abstract
Microwave ablation (MWA) is a type of minimally invasive cancer therapy that uses heat to induce necrosis in solid tumours. Inter- and post-ablational size changes can influence the accuracy of control imaging, posing a risk of incomplete ablation. The present study aims to explore post-ablation 3D size dynamics in vivo using computed tomography (CT). Ten MWA datasets obtained in nine healthy pigs were used. Lesions were subdivided along the z-axis with an additional planar subdivision into eight subsections. The volume of the subsections was analysed over different time points, subsequently colour-coded and three-dimensionally visualized. A locally weighted polynomial regression model (LOESS) was applied to describe overall size changes, and Student's t-tests were used to assess statistical significance of size changes. The 3D analysis showed heterogeneous volume changes with multiple small changes at the lesion margins over all time points. The changes were pronounced at the upper and lower lesion edges and characterized by initially eccentric, opposite swelling, followed by shrinkage. In the middle parts of the lesion, we observed less dimensional variations over the different time points. LOESS revealed a hyperbolic pattern for the volumetric changes with an initially significant volume increase of 11.6% (111.6% of the original volume) over the first 32 minutes, followed by a continuous decrease to 96% of the original volume (p < 0.05).
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Microwave Ablation
en
dc.subject
Porcine Model
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Exploring Patterns of Dynamic Size Changes of Lesions after Hepatic Microwave Ablation in an In Vivo Porcine Model
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
805
dcterms.bibliographicCitation.doi
10.1038/s41598-020-57859-1
dcterms.bibliographicCitation.journaltitle
Scientific Reports
dcterms.bibliographicCitation.originalpublishername
Nature Publishing Group
dcterms.bibliographicCitation.volume
10
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
31965024
dcterms.isPartOf.eissn
2045-2322