dc.contributor.author
Buchert, Ralph
dc.contributor.author
Lange, Catharina
dc.contributor.author
Spehl, Timo S.
dc.contributor.author
Apostolova, Ivalya
dc.contributor.author
Frings, Lars
dc.contributor.author
Jonsson, Cathrine
dc.contributor.author
Meyer, Philipp T.
dc.contributor.author
Hellwig, Sabine
dc.date.accessioned
2019-08-21T12:34:30Z
dc.date.available
2019-08-21T12:34:30Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/25335
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-4039
dc.description.abstract
Introduction: The specific uptake size index (SUSI) of striatal FP-CIT uptake is independent of spatial resolution in the SPECT image, in contrast to the specific binding ratio (SBR). This suggests that the SUSI is particularly appropriate for multi-site/multi-camera settings in which camera-specific effects increase inter-subject variability of spatial resolution. However, the SUSI is sensitive to inter-subject variability of striatum size. Furthermore, it might be
more sensitive to errors of the estimate of non-displaceable FP-CIT binding. This study compared SUSI and SBR in the multi-site/multi-camera (MULTI) setting of a prospective multi-center study and in a mono-site/mono-camera (MONO) setting representative of clinical routine.
Methods: The MULTI setting included patients with Parkinson’s disease (PD, n = 438) and healthy controls (n = 207) from the Parkinson Progression Marker Initiative. The MONO setting included 122 patients from routine clinical patient care in whom FP-CIT SPECT had been performed with the same double-head SPECT system according to the same acquisition and reconstruction protocol. Patients were categorized as “neurodegenerative” (n = 84) or “non-neurodegenerative” (n = 38) based on follow-up data. FP-CIT SPECTs were stereotactically normalized to MNI space. SUSI and SBR were computed for caudate, putamen, and whole striatum using unilateral ROIs predefined in MNI space. SUSI analysis was repeated in native patient space in the MONO setting. The area (AUC) under the ROC
curve for identification of PD/“neurodegenerative” cases was used as performance measure.
Results: In both settings, the highest AUC was achieved by the putamen (minimum over both hemispheres), independent of the semi-quantitative method (SUSI or SBR). The putaminal SUSI provided slightly better performance with ROI analysis in MNI space compared to patient space (AUC = 0.969 vs. 0.961, p = 0.129). The SUSI (computed in MNI space) performed slightly better than the SBR in the MULTI setting (AUC = 0.993 vs. 0.991, p = 0.
207) and slightly worse in the MONO setting (AUC = 0.969 vs. AUC = 0.976, p = 0.259). There was a trend toward larger AUC difference between SUSI and SBR in the MULTI setting compared to the MONO setting (p = 0.073). Variability of voxel intensity in the reference region was larger in misclassified cases compared to correctly classified cases for both SUSI and SBR (MULTI setting: p = 0.007 and p = 0.012, respectively).
Conclusions: The SUSI is particularly useful in MULTI settings. SPECT images should be stereotactically normalized prior to SUSI analysis. The putaminal SUSI provides better diagnostic performance than the SUSI of the whole striatum. Errors of the estimate of non-displaceable count density in the reference region can cause misclassification by both SUSI and SBR, particularly in borderline cases. These cases might be identified by visual checking FP-CIT uptake in the reference region for particularly high variability.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
Dopamine transporter
en
dc.subject
Semi-quantitative analysis
en
dc.subject
Specific uptake size index
en
dc.subject
Specific binding ratio
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Diagnostic performance of the specific uptake size index for semi-quantitative analysis of I-123-FP-CIT SPECT: harmonized multi-center research setting versus typical clinical single-camera setting
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
37
dcterms.bibliographicCitation.doi
10.1186/s13550-019-0506-9
dcterms.bibliographicCitation.journaltitle
EJNMMI Research
dcterms.bibliographicCitation.originalpublishername
SpringerOpen
dcterms.bibliographicCitation.volume
9
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
31065816