dc.contributor.author
Darvin, Maxim E.
dc.contributor.author
Choe, Chun-Sik
dc.contributor.author
Schleusener, Johannes
dc.contributor.author
Lademann, Jürgen
dc.date.accessioned
2019-07-22T14:55:51Z
dc.date.available
2019-07-22T14:55:51Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/25137
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-2892
dc.description.abstract
Confocal Raman microscopy has a number of advantages in investigating the human stratum corneum (SC) in vivo and ex vivo. The penetration profiles of xenobiotics in the SC, as well as depth profiles of the physiological parameters of the SC, such as the concentration of water depending on the strength of hydrogen bonds, total water concentration, the hydrogen bonding state of water molecules, concentration of intercellular lipids, the lamellar and lateral packing order of intercellular lipids, the concentration of natural moisturizing factor molecules, carotenoids, and the secondary and tertiary structure properties of keratin are well investigated. To consider the depth-dependent Raman signal attenuation, in most cases a normalization procedure is needed, which uses the main SC’s protein keratin-related Raman peaks, based on the assumption that keratin is homogeneously distributed in the SC. We found that this assumption is not accurate for the bottom part of the SC, where the water concentration is considerably increased, thus, reducing the presence of keratin. Our results demonstrate that the bottom part of the SC depth profile should be multiplied by 0.94 in average in order to match this non-homogeneity, which result in a decrease of the uncorrected values in these depths. The correctly normalized depth profiles of the concentration of lipids, water, natural moisturizing factor and carotenoids are presented in this work. The obtained results should be taken into consideration in future skin research using confocal Raman microscopy.
en
dc.rights.uri
https://doi.org/10.1364/OA_License_v1
dc.subject
stratum corneum
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Non-invasive depth profiling of the stratum corneum in vivo using confocal Raman microscopy considering the non-homogeneous distribution of keratin
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.doi
10.1364/BOE.10.003092
dcterms.bibliographicCitation.journaltitle
Biomedical Optics Express
dcterms.bibliographicCitation.number
6
dcterms.bibliographicCitation.originalpublishername
Optical Society of America (OSA)
dcterms.bibliographicCitation.pagestart
3092
dcterms.bibliographicCitation.pageend
3103
dcterms.bibliographicCitation.volume
10
dcterms.rightsHolder.url
https://doi.org/10.1364/OA_License_v1
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
31259076
dcterms.isPartOf.issn
2156-7085