dc.contributor.author
Pilger, Daniel
dc.contributor.author
Sonnleithner, Christoph von
dc.contributor.author
Bertelmann, Eckart
dc.contributor.author
Maier, Anna-Karina B.
dc.contributor.author
Joussen, Antonia M.
dc.contributor.author
Torun, Necip
dc.date.accessioned
2019-04-18T15:06:23Z
dc.date.available
2019-04-18T15:06:23Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/24466
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-2237
dc.description.abstract
Objective Descemet membrane endothelial keratoplasty (DMEK) remains a challenging technique. We compare the precision of femtosecond laser-assisted DMEK to manual DMEK. Methods and Analysis A manual descemetorhexis (DR) of 8 mm diameter was compared with a femtosecond laser-assisted DR of the same diameter (femto-DR) in 22 pseudophakic patients requiring DMEK. We used OCT images with a centred xy-diagram to measure the postoperative precision of the DR and the amount of endothelial denuded area. Endothelial cell loss (ECL) and best corrected visual acuity were measured 3 months after surgery. Results In the manual group, the median error of the DR was 7% (range 3%-16%) in the x-diameter and 8% (range 2%-17%) in the y-diameter. In the femto group, the median error in the respective x and y-diameters was 1% (range 0.4%-3%) and 1% (range 0.006%-2.5%), smaller than in the manual group (p=0.001). Endothelial denuded areas were larger in the manual group (11.6 mm(2), range 7.6-18 mm(2)) than in the femto group (2.5 mm(2), range 1.25.9 mm(2)) (p<0.001). The ECL was 21% (range 5%-78%) in the manual DR and 17% (range 6%-38%) in the femto-DR group (p=0.351). The median visual acuity increased from 0.4 logMAR (range 0.6-0.4 logMAR) in both groups to 0.1 logMAR (range 0.4-0 logMAR) in the manual group and to 0.1 logMAR (range 0.3-0 logMAR) in the femto group (p=0.461). Three rebubblings were required in the manual group, whereas the femto group required only one. Conclusion The higher precision of the femto-DR bears the potential to improve DMEK surgery.
en
dc.rights.uri
https://creativecommons.org/licenses/by-nc/4.0/
dc.subject
treatment surgery
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Exploring the precision of femtosecond laser-assisted descemetorhexis in Descemet membrane endothelial keratoplasty
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
e000148
dcterms.bibliographicCitation.doi
10.1136/bmjophth-2018-000148
dcterms.bibliographicCitation.journaltitle
BMJ Open Ophthalmology
dcterms.bibliographicCitation.number
1
dcterms.bibliographicCitation.originalpublishername
BMJ Publishing Group
dcterms.bibliographicCitation.volume
3
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
30687781
dcterms.isPartOf.issn
2397-3269