dc.contributor.author
Sonnenberg, Hauke
dc.date.accessioned
2018-06-07T16:18:17Z
dc.date.available
2011-03-16T09:57:57.816Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/2344
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-6545
dc.description.abstract
Ziel der vorliegenden Arbeit war es, zu prüfen, ob ein Zusammenhang zwischen
der digital gemessenen Rektaltemperatur und der subcutan gemessenen Temperatur
mittels eines Temperaturtranspondersystems existiert. Des Weiteren sollte
geklärt werden, inwieweit das Transpondersystem im Rahmen der
Gesundheitsüberwachung von grossen Versuchstieren (Schweinen), die aus
landwirtschaftlicher Produktion stammen, geeignet ist. Die
Temperaturtransponder (IPTT- 100, Firma PLEXX, Elst, Niederlande) wurden an
insgesamt 21 Läuferschweinen (14 weibliche und sieben männliche Tiere)
getestet. Für die Lokalisationen der Temperaturtransponder wurden folgende
vier Positionen ausgewählt: unter dem Scutulum (cartilago scutiformis) am
linken Ohr, und jeweils an der rechten Körperseite am Ohrgrund, am Ansatz der
letzten Rippe sowie am Schwanzansatz. Alle Tiere wurden vor der Applikation
der Transponder mit Azaperon und Ketamin narkotisiert, was eine sehr gute
Handhabung der Tiere zur Folge hatte. Anschliessend wurden die Tiere gereinigt
und die vier Injektionsorte für die Transponder desinfiziert. Bei nur einem
Tier konnte nach der Injektion der Transponder an nur einer Position
(Scutulum) eine lokal entzündliche Reaktion festgestellt werden. Die
Ergebnisse dieser Arbeit lassen die Schlussfolgerung zu, dass hygienisches
Arbeiten einen positiven Effekt auf die Einheilung der Transponder hat und so
entzündliche Reaktionen, Abszessbildungen und Transponderverluste minimiert
werden können. Beim Applizieren der Transponder hat es sich als hilfreich
herausgestellt, die Injektionskanüle ca. einen cm subcutan vorzuschieben und
dann den Transponder abzulegen. Auch sollte die Einstichwunde nach dem
Entfernen der Injektionskanüle zusammengedrückt werden. Die Untersuchungen
wurden unter praxisnahen Bedingungen durchgeführt. Zu einem definierten
Zeitpunkt wurden einmal täglich mit einem mobilen Lesegerät die
Temperaturtransponder ausgelesen. Zeitgleich erfolgte die Messung der
Rektaltemperatur mittels eines handelsüblichen digitalen Thermometers als
Referenztemperatur. Die rektal gemessenen Temperaturen lieferten plausible
Werte und stimmen mit denen in der Literatur beschriebenen Werten überein. Die
Werte der Temperaturtransponder variierten in vielen Fällen sehr stark. Bei
nur 20 Korrelationsberechnungen konnte eine signifikante Korrelation
aufgedeckt werden und auch unter diesen variierten die
Korrelationskoeffizienten stark. Bei den restlichen Korrelationen kann nicht
vom Zufall unterschieden werden. Mittels der Korrelationsanalyse lässt sich
keine generelle Bestimmung für einen Zusammenhang der jeweiligen
Transponderposition mit der Rektaltemperatur beschreiben. Bei der Berechnung
der Regression stellte sich heraus, dass bei den Regressionsparametern a und b
die Spannweiten aber auch die Lagebereiche der Konfidenzintervalle stark
schwankten und dadurch keine generelle Regressionsgleichung für die Beziehung
der jeweiligen Transponderpositionen zur Rektaltemperatur beschrieben werden
kann. Von 84 Transpondern zeigten 27 Funktionsausfälle. Von diesen 27
Funktionsausfällen konnten fünf auf Transponderverluste und 14 auf
Beschädigungen oder Glasbruch der Transponderhülle zurückgeführt werden. Für
acht Transponder konnte kein Grund festgestellt werden. Für die
Funktionsausfälle gibt es verschiedene Erklärungen, z.B. mechanische Einflüsse
auf den Transponder oder Herausdrücken des Transponders aus dem
Injektionskanal. Schwankungen der Hauttemperatur sind u.a. bedingt durch
Umwelteinflüsse, Verhalten der Tiere und physikalische Prozesse, wie z.B.
Konvektion, Konduktion, Radiation und Verdunstung. Abschliessend kann in der
von mir durchgeführten Arbeit als Ergebnis festgestellt werden, dass die
Messung der Hauttemperatur mit Hilfe eines Temperaturtranspondersystems eine
zu ungenaue Methode darstellt, um Rückschlüsse auf die Rektaltemperatur
schliessen zu können. Die Hauttemperaturmessung mittels eines
Transpondersystems ist ein hochsensibles Verfahren, wobei jedoch zu viele
Faktoren den zu messenden Temperaturwert beeinflussen können. Diese Faktoren
zu kontrollieren und eventuell zu neutralisieren erscheint zu aufwendig und
kaum durchführbar. Beim Schwein spielen tierartspezifische Besonderheiten wie
z.B. das Verhalten sowie erhöhte Stressanfälligkeit eine wichtige Rolle. Die
Ergebnisse der vorliegenden Arbeit gelten somit nur für Schweine und sind
nicht auf andere Tierarten mit den entsprechenden arttypischen
Umweltbedingungen bzw. Verhalten anwendbar.
de
dc.description.abstract
Aim of the current study was to determine a correlation between the digitally
measured rectal temperature and the subcutaneously measured temperature, by
means of a temperature transponder system, in pigs. In addition it was
examined to what degree the transponder system would be valuable in the
supervision of the health status of large laboratory animals (e.g. pigs)
originating from agricultural production systems. The temperature transponders
(IPTT- 100, Company PLEXX, Elst, Netherlands), were tested on 21 pigs (14
females, seven males). For the localization of the transponders the following
four sites were chosen: under the scutulum (cartilago scutiformis) of the left
ear, and, all on the right side of the body, at the base of the ear,
articulation of the last rib, and at the base of the tail. All animals were
anaesethised with azaperon and ketamine before transponder implantation, which
resulted in an easy handling of the animals afterwards. After implantation the
animals were cleaned and the implantation sites disinfected. Only one animal,
and only at one site (scutulum), developed a local inflammatory reaction after
injection of the transponder. The results of this study propose that hygiene
has a positive effect on the healing of the transponder sites, and minimizes
inflammatory reactions and abscess formations at the transponder site as well
as transponder losses. It proofed to be helpful to advance the injection
needle approximately one cm subcutaneously before depositing the transponder
and to apply pressure on the injection site after removal of the needle. The
examinations were conducted under practice like condition. Once a day, at a
set time, the transponders were red via a mobile reader and concurrently the
rectal temperature was measured with a commercial digital thermometer as a
reference temperature. The rectally measured temperatures were within normal
limits according to published literature. The values of the temperature
transponders varied in many of the measurements. Out of only 20 correlation
measurements one correlation could be determined as significant, and even in
between these the correlation coefficients varied greatly. The other
correlations could not be set apart from coincidence. Using the correlation
analysis, at different positions measured transponder temperatures, could not
be put into context with the rectally measured temperatures. When calculating
the regression it turned out that, looking at the regression parameters a and
b, the range as well as the position of the confidence intervals varied
greatly making it impossible to determine a general regression formula for the
relationship between the transponder sites and the rectal temperatures. Out of
84 transponders 27 showed functional failures. Out of those 27 failures five
were due to transponder losses and14 due to damage or breaking of the glass
casing of the transponder. In eight cases the cause of failure could not be
determined but possible explanations could be mechanical influences on the
transponder or pushing of the transponder out of the injection canal.
Variation of the skin temperature can be due to environmental influences,
animal behaviour and physical processes like convection, conduction, radiation
and evaporation. In conclusion, it can be determined with this current study,
that the measurement of the skin temperatures via a transponder system does
not provide an accurate method to draw conclusions about the rectal
temperature. The measurement of the skin temperature with the transponder
system is a very sensitive procedure which can still be influenced by too many
factors. It seems too difficult to control or neutralize these factors and, in
pigs, species specific features, such as behaviour and stress susceptibility
play an important role. The results of this study are only valid for pigs and
are not applicable to other species with species specific environmental and
behavioural conditions.
en
dc.format.extent
IV, 146 S.
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject
body temperature
dc.subject
thermoregulation
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::630 Landwirtschaft::630 Landwirtschaft und verwandte Bereiche
dc.title
Untersuchungen der Körpertemperatur an Versuchsschweinen, ermittelt mit der
Transpondertechnik an verschiedenen Implantationsorten im Vergleich zur rektal
gemessenen Körpertemperatur
dc.contributor.firstReferee
PD Dr. Ch. Große-Siestrup
dc.contributor.furtherReferee
Prof. Dr. K. H. Lahrmann
dc.contributor.furtherReferee
Prof. Dr. H. Tönhardt
dc.date.accepted
2010-06-30
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000021695-2
dc.title.translated
Examinations of the body temperature on experimental pigs, established with
the transponder technique at different implantation sites in comparison to
rectally measured body temperatures
en
refubium.affiliation
Veterinärmedizin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000021695
refubium.note.author
Mensch und Buch Verlag
refubium.mycore.derivateId
FUDISS_derivate_000000009210
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access