dc.description.abstract
AIM: To compare IOPen and ICare rebound tonometry to Goldmann applanation
tonometry (GAT) according to International Standards Organization (ISO) 8612
criteria. METHODS: Totally 191 eyes (n=107 individuals) were included.
Criteria of ISO 8612 were fulfilled: 3 clusters of IOP, measured by GAT, were
formed. The GAT results were given as mean±standard deviation. RESULTS: GAT
(19.7±0.5 mm Hg) showed a significant correlation to ICare (19.8±0.5 mm Hg)
(r=0.547, P<0.001) and IOPen (19.5±0.5 mm Hg) (r=0.526, P<0.001). According to
ISO 8612 criteria in all 3 IOP groups the number of outliers (of the 95%
limits of agreement) exceeded 5% for ICare and IOPen vs GAT: No.1 (n=68) 29.4%
and 22.1%, No.2 (n=62) 35.5% and 37.1%, No.3 (n=61) 26.2% and 42.6%,
respectively. CONCLUSION: The strict requirements of the ISO 8612 are not
fulfilled in a glaucoma collective by ICare and IOPen at present. As long as
the Goldmann tonometry is applicable it should be used first of all for
reproducible IOP readings. ICare and IOPen tonometry should be considered as
an alternative tool, if application of Goldmann tonometry is not possible.
de
dc.rights.uri
http://www.ijo.cn/gjyken/ch/first_menu.aspx?parent_id=20120104165221001
dc.subject
ICare tonometry
dc.subject
IOPen tonometry
dc.subject
Goldmann applanation tonometry
dc.subject
intraocular pressure
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit
dc.title
Comparison of ICare and IOPen vs Goldmann applanation tonometry according to
international standards 8612 in glaucoma patients
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation
International Journal of Ophthalmology. - 9 (2016), 11, S. 1624-1628
dcterms.bibliographicCitation.doi
10.18240/ijo.2016.11.14
dcterms.bibliographicCitation.url
http://www.ijo.cn/gjyken/ch/reader/view_abstract.aspx?file_no=20161114&flag=1
refubium.affiliation
Charité - Universitätsmedizin Berlin
de
refubium.mycore.fudocsId
FUDOCS_document_000000026111
refubium.resourceType.isindependentpub
no
refubium.mycore.derivateId
FUDOCS_derivate_000000007499
dcterms.accessRights.openaire
open access