dc.contributor.author
Unterhalt, Holger
dc.date.accessioned
2018-06-08T00:52:55Z
dc.date.available
2002-07-16T00:00:00.649Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/12602
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-16800
dc.description
Titel, Danksagung
Abkürzungen
Inhaltsverzeichnis
1 Einleitung 1
2 Theorie der SFG an Oberflächen 5
3 Apparativer Aufbau und Experimentelles 33
4 Messungen an Pt(111) 61
5 Messungen an Pd(111) 67
6 Messungen an Pd/Al2O3/NiAl(110) 93
7 Polarisationsabhängige Messungen 161
8 Reaktionen 177
9 Zusammenfassung 189
Anhang 193
Literaturverzeichnis 233
dc.description.abstract
Summenfrequenzerzeugungsspektroskopie (SFG) ist eine nichtlinear optische,
oberflächensensitive und druckunabhängige Methode, welche die Aufnahme von
Schwingungsspektren im Druckbereich vom Ultrahochvakuum (UHV) bis zu etwa 1
bar ermöglicht. Im Rahmen dieser Dissertation wurden zur Präparation und
Untersuchung von Modellkatalysatoren eine Ultrahochvakuumkammer mit
Hochdruckzelle und zwei SFG-Spektrometer entwickelt, die auf unterschiedlichen
Pikosekundenlasersystemen (Ti:Sa bzw. Nd:YAG) basieren. Die Eignung der
Instrumentation wurde mit der Untersuchung der Adsorption von Kohlenmonoxid
und Ethylen auf einer Vielzahl von Modellkatalysatoren in Gasphasen des
genannten Druckbereichs und unter Reaktionsbedingungen demonstriert.
In SFG-Spektren von CO/Pt(111) wurden bei Drücken bis zu 500 mbar keine
Hochdruckspezies detektiert - im Gegensatz zu Ergebnissen anderer
Arbeitsgruppen. Es wird ausführlich auf die Notwendigkeit einer
Gasphasenkompensation eingegangen.
Umfassende Messungen am System CO/Pd(111) bis 1000 mbar ergaben, daß die
Adsorbatstrukturen, die bei tiefen Temperaturen im Hochvakuum präpariert
werden, auch bei hohen Oberflächentemperaturen erzeugt werden können - bei
entsprechend hohen Drücken. Bei der Bestimmung des Neigungswinkels von CO auf
der Pd(111)-Oberfläche in polarisationsabhängigen Messungen ergab sich eine
starke Modellabhängigkeit.
Bei ersten SFG-Messungen der CO-Adsorption auf geträgerten Palladium-
Nanoteilchen (Pd/Al2O3/NiAl(110)) verschiedener Größe (< 10 nm) und
Morphologie mit dem Ti:Sa-Spektrometer fand sich im Hochvakuum auf
ungeordneten Partikeln gegenüber facettierten Partikeln ein größeres on-top-
Signal. Das Signal des bridge-CO auf beiden Sorten von Nanoteilchen entsprach
in seiner Frequenz eher dem defektreicher Pd(111)-Oberflächen. Bei hohen
Drücken von einigen hundert mbar konnte eine stärkere Bevölkerung der on-top-
Plätze auch auf den facettierten Partikeln erreicht werden. Mit dem besser
auflösenden Nd:YAG-Spektrometer wurde auf facettierten Partikeln im Hochvakuum
wie bei hohen Drücken zusätzlich ein hollow-Signal und eine zweite bridge-
Spezies, die dem CO auf (111)-Facetten zugeordnet wurde, nachgewiesen. In den
Spektren facettierter Partikel wurde damit eine Komponente identifiziert, die
sich im Hochvakuum bei tiefen Temperaturen und unter Hochdruck analog
CO/Pd(111) verhält. Unterschiede zur Pd(111)-Oberfläche sind in der
Heterogenität der Partikel begründet. Die Nanopartikelspektren der beiden
Spektrometer zeigten unterschiedliche Linienformen (Absorptions- bzw.
Dispersionskurven). Dies ist Folge des Unterschieds im nichtresonanten
Hintergrund, der wahrscheinlich in den verschiedenen (vis-)Laserwellenlängen
begründet ist. In Messungen mit dem Nd:YAG-Spektrometer fand sich außerdem
eine Abhängigkeit der Linienform von der verwendeten Polarisationskombination
(ppp bzw. ssp).
Die Eignung des experimentellen Aufbaus für die Untersuchung heterogener
Reaktionen mit SFG-Spektroskopie und gleichzeitiger gaschromatographischer
Gasphasenanalyse wurde anhand der CO-Hydrierung und der Ethylenhydrierung
gezeigt.
de
dc.description.abstract
Sum frequency generation spectroscopy (SFG) is a nonlinear optical, surface
sensitive and pressure independent method allowing to acquire vibrational
spectra in a pressure range from ultrahigh vacuum (UHV) up to about 1 bar.
During this thesis work an ultrahigh vacuum chamber with high pressure cell
and two SFG spectrometers based on different picosecond laser systems (Ti:Sa
and Nd:YAG) were developed for preparation and investigation of model
catalysts. The suitability of the setup was demonstrated in studies of the
adsorption of carbon monoxide and ethylene on a multitude of model catalysts
in the pressure range mentioned above and under reaction conditions.
In SFG spectra of the system CO/Pt(111) at pressures up to 500 mbar no high
pressure species were detected - contrary to results obtained by other groups.
The necessity of performing a compensation for gas-phase absorption is treated
in detail.
Extensive measurements of CO/Pd(111) up to 1000 mbar showed, that adsorbate
structures prepared at low temperatures in high vacuum can also be obtained at
high surface temperatures - at accordingly high pressures. Determination of
the tilt angle of CO on Pd(111) in polarization dependent measurements showed
a strong dependency on the model used.
In first SFG measurements of CO adsorption on supported Palladium
nanoparticles (Pd/Al2O3/NiAl(110)) of different size (< 10 nm) and morphology
with the Ti:Sa spectrometer, in high vacuum the signal of on-top CO on
disordered particles was bigger than that on faceted particles. The frequency
of the bridge signal on both kinds of nanoparticles corresponded to that found
on defective Pd(111) surfaces. At high pressures of a few hundred mbar a
higher population of on-top sites could be reached also for the faceted
particles. With the better resolution of the Nd:YAG spectrometer in addition
hollow CO and a second bridge species attributed to CO on (111) facets were
detected on faceted particles, in high vacuum and at high pressure. Thus, in
spectra of faceted particles a component was identified that behaves in high
vacuum at low temperatures and at high pressure analogously to CO/Pd(111).
Differences to the Pd(111) surface are caused by the heterogeneity of the
particles. The nanoparticle spectra recorded with the two spectrometers showed
different lineshapes (absorption vs. dispersion curves). This results from the
difference in the non resonant background, that is probably caused by the
differing (vis-)laser wavelengths. In measurements with the Nd:YAG
spectrometer also an dependency of the lineshape on the polarization
combination (ppp or ssp) used was found.
The suitability of the experimental setup for investigations of heterogeneous
reactions with SFG spectroscopy and simultaneous gas-phase analysis by gas
chromatography was demonstrated by measurements of CO hydrogenation and
ethylene hydrogenation.
en
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject.ddc
500 Naturwissenschaften und Mathematik::530 Physik::530 Physik
dc.title
Summenfrequenzerzeugungsspektroskopie an Platin- und Palladium-
Modellkatalysatoren
dc.contributor.firstReferee
Prof. Dr. Hans-Joachim Freund
dc.contributor.furtherReferee
Prof. Dr. Nikolaus Schwentner
dc.date.accepted
2002-06-19
dc.date.embargoEnd
2002-07-17
dc.identifier.urn
urn:nbn:de:kobv:188-2002001234
dc.title.translated
Sum Frequency Generation Spectroscopy on Platinum and Palladium Model
Catalysts
en
refubium.affiliation
Physik
de
refubium.mycore.fudocsId
FUDISS_thesis_000000000678
refubium.mycore.transfer
http://www.diss.fu-berlin.de/2002/123/
refubium.mycore.derivateId
FUDISS_derivate_000000000678
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access