dc.contributor.author
Liekfeld, Anja
dc.date.accessioned
2018-06-07T15:28:39Z
dc.date.available
2007-02-22T00:00:00.649Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/1128
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-5330
dc.description
Titelblatt und Inhaltsverzeichnis
Einleitung und Fragestellung
Ziel der vorliegenden Untersuchungen
Material und Methoden
Ergebnisse
Diskussion
Zusammenfassung und Ausblick
Literaturverzeichnis
dc.description.abstract
Für die Evaluierung das Nachstars kommen verschiedene Methoden zum Einsatz.
Dies sind Untersuchungen in vivo, postmortem, tierexperimentell oder in vitro
an unterschiedlichen Modellen. Ein ideales System zur Nachstar-untersuchung
sollte kliniknah, von geringem zeitlichen und materiellen Aufwand sein,
prospektive und vergleichende Untersuchungen ermöglichen, vor allem auch von
Intraokularlinsen, bevor sie klinisch eingesetzt werden, um vor Anwendung in
der Katarakt-Chirurgie bereits feststellen zu können, ob das entsprechende
Modell nachstarinhibitorische Potenzen aufweist. Das in dieser Arbeit
beschriebene und angewandte humane Kapselsack-Modell scheint uns diesen
Anforderungen am nächsten zu kommen. Es ist vor allem für vergleichende
Untersuchungen aufgrund der möglichen Paarvergleiche an einem Spenderbulbi-
Paar geeignet. Zur Evaluation des Modells wurden in dieser Arbeit verschiedene
Intraokularlinsen (IOL) hinsichtlich des Linsenepithelzell(LEC)-Wachstums
untersucht. Es wurden Akryllinsen, PMMA-Linsen, Multifokallinsen und
Silikonlinsen mit spezieller Randgestaltung untersucht. Die in vitro Daten
wurden mit klinischen Daten aus der Literatur verglichen, wenn vorhanden.
Außerdem wurden die entsprechenden IOLs auch klinisch hinsichtlich ihres
Nachstarverhaltens untersucht. Dabei kam das EPCO-System zum Einsatz. Dabei
konnte für das Kapselsack-Modell eine gute Korrelation zu klinischen Daten
ermittelt werden, so dass dieses Modell sehr geeignet für eine prospektive
Untersuchung von IOLs hinsichtlich des Nachstar-Verhaltens im Sinne eines
Zeitraffer-Modells erscheint.
de
dc.description.abstract
Purpose: To investigate the effect of different intraocular lenses (IOLs) on
lens epithelial cells (LEC) and on human capsular bags in vitro and to
evaluate the transferability of this model to clinical situations. Methods:
Sham cataract surgery, including IOL-into-the-bag implantation, was performed
on donor eyes after removal of the cornea. The capsular bag including the IOL
was removed, pinned on a culture dish, covered with medium, and incubated. Two
different IOLs were compared per pair of donor eyes. In each pair of donor
eyes, the two different IOLs to bi compared were implanted individually into
capsular bags. The time required for complete coverage of the posterior
capsule by a confluent monolayer of LECs was documented. The following IOLs
were compared: three-piece acrylic IOLs of different sizes, single-piece
polymethylmethacrylate (PMMA) IOLs, single-piece acrylic IOLs with different
material properties, silicone IOLs with different edge properties, multifocal
IOLs. Some of the IOLs were also compared clinically in terms of secondary
cataract. The EPCO system was used for evaluation. Results: The shortes period
of time for LEC coverage of the posterior capsule was significantly seen for
the PMMA IOLs. There was no difference for the acrylic IOLs or the multifocal
IOLs, but a significant difference for the two models of silicone IOLs with a
faster LEC coverage for the IOL with the specific Fresnel edge design. The
clinical data show correspondence to the in vitro results. Conclusion: The
human capsular bag model employed allows short-term evaluation of secondary
cataract formation for different IOLs. This model s correlation with clinical
results is good.
en
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject
acrylic lenses
dc.subject
multifocal lense
dc.subject
lens epithelial cells
dc.subject
secondary cataract
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Humanes Kapselsackmodell zur Nachstaruntersuchung nach Implantation von
Intraokularlinsen - Evaluation und Anwendung
dc.contributor.firstReferee
Professor Dr. Holger Busse
dc.contributor.furtherReferee
Professor Dr. Peter Kroll
dc.date.accepted
2007-01-22
dc.date.embargoEnd
2007-03-20
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000002734-4
dc.title.translated
Evaluation of a human capsular bag model for secondary cataract determination
after intraocular lens implantation
en
refubium.affiliation
Charité - Universitätsmedizin Berlin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000002734
refubium.mycore.transfer
http://www.diss.fu-berlin.de/2007/172/
refubium.mycore.derivateId
FUDISS_derivate_000000002734
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access