dc.contributor.author
Jaroch, Martin
dc.date.accessioned
2018-06-07T23:16:46Z
dc.date.available
2009-03-30T13:02:40.929Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/10286
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-14484
dc.description.abstract
Problemstellung: Die erfolgreiche und vor allem langfristige
Desensibilisierung von Dentinwunden kann mit den derzeitigen
Therapiemöglichkeiten nicht erreicht werden. Zielsetzung: Das Ziel dieser In-
vitro-Studie war, die Oberflächenresistenz, die Penetrationseigenschaften und
die Auswaschphänomene von unterschiedlichen Materialien zur langfristigen
Desensibilisierung von freiliegenden Dentinoberflächen zu untersuchen.
Material und Methoden: Die Schichtdicke an den Dentinoberflächen, das
Penetrationsvermögen und die Anzahl gefüllter Dentinkanälchen von drei
Adhäsiven (Excite, Ivoclar Vivadent; Solobond M, Voco; Xeno V, Dentsply), zwei
Desensibilisierern (Gluma, Heraeus Kulzer; Vivasens, Ivoclar Vivadent), einem
Fluoridlack (Duraphat, Colgate-Palmolive) und einem Fissurenversiegler (Dyract
Seal, Dentsply) wurden auf 64 Proben aus dem Zahnhalsbereich extrahierter
Zähne (n = 8 je Gruppe) nach den Zahnputzintervallen von 0, 2, 7, 14, 28 und
86 Tagen mit dem konfokalen Laser-Raster-Mikroskop (CLSM) untersucht.
Ergebnisse: Die Initial vorhandenen Materialschichten an der Dentinoberfläche
wurden nach wenigen Tagen durch das Zähneputzen vollständig entfernt (Excite
28 d; Solobond M 28 d; Xeno V 28 d; Dyract Seal 14 d; Duraphat 2 d; Gluma 7 d;
Vivasens 14 d). Die Materialien zeigten unterschiedliche Penetrationsvermögen
der oberflächlichen Dentinkanälchen (<40 µm) [(MW ± SD); Excite (62 % ± 24 %),
Solobond M (69 % ± 42 %), Xeno V (45 % ± 34 %), Dyract Seal (61 % ± 31 %),
Gluma (29 % ± 23 %), Duraphat (54 % ± 32 %), Vivasens (72 % ± 27 %)]. Zudem
waren nach 86 Tagen deutliche Auswasch-phänomene der oberflächlich gefüllten
Bereiche (<40µm) feststellbar [Excite (46 % ± 22 %), Solobond M (41 % ± 39 %),
Xeno V (21 % ± 15 %), Dyract Seal (39 % ± 39 %), Gluma (28 % ± 20 %), Duraphat
(9 % ± 8 %), Vivasens (26 % ± 25 %)]. Schlussfolgerungen: Die
Oberflächenschichten der untersuchten Materialien konnten der me-chanischen
Beanspruchung durch das Zähneputzen nicht standhalten. Darüber hinaus war das
Penetrationsvermögen unzureichend und die in die Dentinkanälchen penetrierten
Materialbestandteile konnten bei allen Gruppen ausgewaschen werden. Eine
langfristige klinische Reduktion der Sensibilität ist somit fraglich.
de
dc.description.abstract
Statement of problem: Successful and above all long-term desensitizing of
exposed dentin cannot be achieved with the present therapy techniques.
Objectives: The purpose of this study was to compare the long-term wear
resistance of the surface layers, the penetration ability and long-term
occlusion of seven different products in vitro. Materials and methods: 64
dentin samples, obtained from 32 extracted premolar and molar teeth were used
in this study. These were divided in 8 groups of 8 samples each. The samples
within the groups were treated with the agents immersed in artificial saliva
and connected to dentin liquor simulation. Moreover the samples were subjected
to simulated tooth brushing two times daily during the period of 86 days,
sealed with composite in intervals (0 d, 2 d, 7 d, 14 d, 28 d, 86 d) and
viewed under the confocal laser scanning microscope (CLSM). The agents studied
were Ex-cite, Solobond M, Xeno V, Gluma Desensitizer, Vivasens, Duraphat and
Dyract Seal. Results: The initially existing surface layers could be
completely removed after few days by tooth brushing (Excite 28 d; Solobond M
28 d; Xeno V 28 d; Dyract Seal 14 d; Duraphat 2 d; Gluma 7 d; Vivasens 14 d).
Application of the experimental agents resulted in a significant variance of
the penetration ability in dentinal tubules (<40 µm) [(MD ± SD); Excite (62 %
± 24 %), Solobond M (69 % ± 42 %), Xeno V (45 % ± 34 %), Dyract Seal (61 % ±
31 %), Gluma (29 % ± 23 %), Duraphat (54 % ± 32 %), Vivasens (72 % ± 27 %)].
Furthermore, all experimental agents showed a reduction of the superficially
filled (<40 µm) dentinal tubules. [Excite (46 % ± 22 %), Solobond M (41 % ± 39
%), Xeno V (21 % ± 15 %), Dyract Seal (39 % ± 39 %), Gluma (28 % ± 20 %),
Duraphat (9 % ± 8 %), Vivasens (26 % ± 25 %)]. Conclusions: The materials
could not withstand mechanical load by tooth brushing and cause thus no stable
surface layers. Moreover, the penetration ability was inadequate and
permanently closure of the superficially filled dentinal tubules could not be
achieved. Within the limitations of the study, it can be concluded that long-
term reduction of dentin hypersensitivity treated with the experimental agents
is questionable.
en
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit
dc.title
Untersuchung zur Oberflächenresistenz und Eindringtiefe verschiedener In-
Office-Produkte zur Behandlung hypersensibler Dentinbereiche
dc.contributor.contact
martin.jaroch@charite.de
dc.contributor.firstReferee
Prof. Dr. Andrej M. Kielbassa
dc.contributor.furtherReferee
Prof. Dr. Ralf J. Radlanski
dc.contributor.furtherReferee
Prof. Dr. Stefan Zimmer
dc.date.accepted
2009-06-14
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000009293-5
dc.title.translated
In-vitro long-term evaluation of the wear resistance of various agents used
for the treatment of hypersensitivity
en
refubium.affiliation
Charité - Universitätsmedizin Berlin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000009293
refubium.mycore.derivateId
FUDISS_derivate_000000005355
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access