dc.contributor.author
Prangemeier, Barbara
dc.date.accessioned
2018-06-07T21:12:11Z
dc.date.available
2007-02-11T00:00:00.649Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/7540
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-11739
dc.description
Titel, Autor und Referenten
Inhaltsverzeichnis
1
Einleitung
7
2
Literaturübersicht
9
3
Problemstellung
23
4
Material und Methode
24
5
Ergebnisse
35
6
Diskussion
51
7
Zusammenfassung
62
8
Summary
63
9
Literaturverzeichnis
65
10
Anhang
75
dc.description.abstract
Während sich in den letzten Jahren vollkeramische Kronen in der zahnärztlichen
Praxis zunehmend durchgesetzt haben, scheint es, dass metallfreie
Brückenrestaurationen noch mit großer Vorsicht eingesetzt werden. Ziel dieser
Untersuchung war die Abhängigkeit der Bruchlast viergliedriger, mit dem LAVA-
System CAD/CAM-gefertigter Zirkonoxidkeramikbrücken vom verwendeten
Stumpfmaterial und der Beeinflussung durch Thermocycling in einem Drei-Punkt-
Biegeversuch zu untersuchen. Die verwendeten Stumpfmaterialien, die zur
Anwendung kamen, waren die CAD/CAM-geeigneten Werkstoffe glasfaserverstärkter
Kunststoff (DC-Tell, Fa DCS), LAVA-Zirkonoxidkeramik (3M ESPE) und Messing. Je
zwei Stümpfe einer Werkstoffgruppe wurden in Kunststoff eingebettet, wobei
eine gewisse Eigenbeweglichkeit durch einen Schrumpfschlauch erreicht wurde.
Pro Materialgruppe wurden zwanzig Brücken konventionell mit Zink-
Phosphatzement befestigt und 21 Tage in 0,9%iger Kochsalzlösung
wassergelagert. Anschließend wurde die Hälfte jeder Gruppe einer künstlichen
Alterung mittels Thermocycling unterzogen. Die Ergebnisse der
Bruchlastversuche wurden statistisch deskriptiv und analytisch mithilfe des
T-Testes ausgewertet. Die Ergebnisse zeigten, dass bei Anwendung von Keramik-
oder Metallstümpfen die Bruchlasten der Brücken deutlich über denen bei
Zementierung auf Kunststoffstümpfen lagen. Das künstliche Alterungsverfahren
mittels Thermocycling hatte keinen signifikanten Einfluss im Falle der
Keramik- oder Metallstümpfe, während es tendenziell zu einer deutlichen, aber
nicht signifikanten Reduktion der Bruchlast führte, wenn Vollkeramikbrücken
auf glasfaserverstärkten Kunststoffstümpfen zementiert wurden. Abschließend
ist festzustellen, dass nach den für diese Keramik ermittelten Bruchlasten das
Indikationsgebiet für den Seitenzahnbereich eindeutig gegeben ist. Vorherige
Aufbauten aus Keramik und Metall sind auch unter dauerhafter Beeinflussung von
wechselnden Temperaturen und Flüssigkeiten in der Mundhöhle empfehlenswert.
Über die Verwendung von Kunststoff für den Stumpfaufbau bei der klinischen
Erprobung der Zirkonoxidbrücken kann nach den Ergebnissen dieser Untersuchung
noch keine verlässliche Aussage getätigt werden.
de
dc.description.abstract
Over the last years all-ceramic crowns have gained a larger market-share than
all-ceramic bridges and thus it seems that all-ceramic bridges are implemented
with a great deal of caution. The purpose of this study was to show the
correlation of the fracture-strength of four-unit zirconium-oxide bridges
constructed with the CAD/CAM-designed LAVA-System, in a three point-bending
test. Thereby special attention was placed on the different die materials and
the influence of thermocycling on them. The die materials used were
fibreglass-enforced resins (DC-Tell,Firm DCS), LAVA-Zirconiumoxide-ceramics (3
M ESPE) and yellow brass. Two dies of each material were embedded in Paladur
Clear (Heraeus Kulzer), whereby a defined mobility of the dies was reached by
a heat shrink tubing (3 M, type HSR) which was previously wrapped around the
dental roots. For each group of die materials 20 bridges were cemented
conventionally with zinc-oxide-phosphate cement (Hoffmann Berlin) and were
then stored in 0,9% Sodiumchloride-solution for 21 days. Subsequently half of
the bridges of each group were aged artificially through thermocycling. The
results of the fracture strength test were analysed and described
statistically with the t-test. The results showed that when using ceramic or
metal dies, the fracture strength of the bridges were clearly higher than the
bridges that were cemented on resin enforced dies. The artificial aging
procedure through thermocycling had no significant influence in the case of
ceramic or metal die materials, whereas it lead to a visible but not
significant reduction of the fracture strength when full-ceramic bridges were
cemented on fibre-enforced resin die material. In conclusion it can be noted
that the fracture strength, that was detected for these ceramics, implies a
clear indication for use in the cantilever region. The previous reconstruction
of teeth using ceramic or brass core materials, even under constant influence
of changing temperatures and fluids in the oral cavity, are clearly
recommended. About the implementation of resin-based core materials, when
testing these bridges clinically, no reliable conclusion can be done.
en
dc.rights.uri
http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen
dc.subject
All Ceramic Keramik Krone Brücke dental fracture strength LAVA Thermocycling core material die
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Einfluss verschiedener Stumpfaufbaumaterialien auf die Bruchlast
viergliedriger CAD / CAM - gefertigter Seitenzahnbrücken aus
Zirkonoxidvollkeramik (LAVA-System) mit künstlicher Alterung durch
Thermocycling
dc.contributor.firstReferee
Prof. Dr. med. dent. Wolfgang B. Freesmeyer
dc.contributor.furtherReferee
Priv. Doz. Dr. med. dent Ingrid Peroz
dc.date.accepted
2007-03-23
dc.date.embargoEnd
2007-04-19
dc.identifier.urn
urn:nbn:de:kobv:188-fudissthesis000000002853-0
dc.title.translated
Influence of Different Core Built Up Materials on the Fracture Strength of
Four-Unit CAD/CAM Constructed All-Ceramic Zirconiumoxide Bridges (LAVA-System)
with Artificial Aging through Thermocycling
en
refubium.affiliation
Charité - Universitätsmedizin Berlin
de
refubium.mycore.fudocsId
FUDISS_thesis_000000002853
refubium.mycore.transfer
http://www.diss.fu-berlin.de/2007/105/
refubium.mycore.derivateId
FUDISS_derivate_000000002853
dcterms.accessRights.dnb
free
dcterms.accessRights.openaire
open access