dc.contributor.author
Hübscher, Anne
dc.contributor.author
Schwerg, Marius
dc.contributor.author
Hoffmann, Saskia
dc.contributor.author
Baldenhofer, Gerd
dc.contributor.author
Heupel, Christian
dc.contributor.author
Jasaityte, Ruta
dc.contributor.author
Kruck, Sebastian
dc.contributor.author
Stangl, Karl
dc.contributor.author
Dreger, Henryk
dc.contributor.author
Knebel, Fabian
dc.date.accessioned
2022-03-02T12:44:55Z
dc.date.available
2022-03-02T12:44:55Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/34275
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-33993
dc.description.abstract
Background: Tenting of the mitral leaflets is a major pathophysiological factor contributing to functional mitral regurgitation (FMR). A novel software tool allows automated quantification of the tenting volume (TnV) by 3D transesophageal echocardiography (TEE). The aims of this study are to investigate the correlations of biometric patient characteristics with the TnV and whether a threshold value for the diagnosis of a moderate or severe FMR can be calculated for the TnV.
Methods: This explorative and hypothesis-generating study analyzed the TnV of the mitral valve obtained by clinically indicated TEE. The mid-systolic, threefold calculated and averaged TnV from 80 patients with no or mild FMR and 27 patients with moderate or severe FMR was determined using the TomTec 4D MV Assessment tool.
Results: The TnV correlated significantly with the body size (r = 0.341), the weight (r = 0.272), and the body surface area (r = 0.320). After the adjustment to the body size, a threshold value of 1.25 cm(3)/m was determined for the TnV by using a receiver-operating characteristic curve. This value distinguished moderate to severe from none to mild FMR with a sensitivity of 85% and a specificity of 71%. The intra-observer variability and inter-observer variability were determined to be 0.96 and 0.85, respectively.
Conclusions: Automated assessment of TnV has the potential to support the diagnostic evaluation of FMR. Further studies are needed to validate this result, detect additional factors influencing the size of the TnV, and determine further thresholds for any degree of FMR.
en
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject
mitral regurgitation
en
dc.subject
three-dimensional echocardiography
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Automated quantification of mitral valve tenting volume in functional mitral regurgitation by three‐dimensional echocardiography
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.doi
10.1111/echo.14759
dcterms.bibliographicCitation.journaltitle
Echocardiography
dcterms.bibliographicCitation.number
7
dcterms.bibliographicCitation.originalpublishername
Wiley
dcterms.bibliographicCitation.pagestart
1043
dcterms.bibliographicCitation.pageend
1048
dcterms.bibliographicCitation.volume
37
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.funding
DEAL Wiley
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
32530513
dcterms.isPartOf.issn
0742-2822
dcterms.isPartOf.eissn
1540-8175