dc.description.abstract
We aimed to evaluate radiomic features' stability across different region of interest (ROI) sizes in CT and MR images. We chose a phantom with a homogenous internal structure so no differences for a feature extracted from ROIs of different sizes would be expected. For this, we scanned a plastic cup filled with sodium chloride solution ten times in CT and per MR sequence (T1-weighted-gradient-echo and T2-weighted-turbo-inversion-recovery-magnitude). We placed sphere-shaped ROIs of different diameters (4, 8, and 16 mm, and 4, 8, and 16 pixels) into the phantom's center. Features were extracted using PyRadiomics. We assessed feature stability across ROI sizes with overall concordance correlation coefficients (OCCCs). Differences were tested for significance with the Mann-Whitney U-test. Of 93 features, 87 T1w-derived, 87 TIRM-derived, and 70 CT-derived features were significantly different between ROI sizes. Among MR-derived features, OCCCs showed excellent (>0.90) agreement for mean, median, and root mean squared for ROI sizes between 4 and 16 mm and pixels. We further observed excellent agreement for 10th and 90th percentile in T1w and 10th percentile in T2w TIRM images. There was no excellent agreement among the OCCCs of CT-derived features. In summary, many features indicated significant differences and only few showed excellent agreement across varying ROI sizes, although we examined a homogenous phantom. Since we considered a small phantom in an experimental setting, further studies to investigate this size effect would be necessary for a generalization. Nevertheless, we believe knowledge about this effect is crucial in interpreting radiomics studies, as features that supposedly discriminate disease entities may only indicate a systematic difference in ROI size.
en
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
texture analysis
en
dc.subject
magnetic resonance imaging
en
dc.subject
computed tomography
en
dc.subject
reproducibility
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
dc.title
Stability of Radiomic Features across Different Region of Interest Sizes—A CT and MR Phantom Study
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.doi
10.3390/tomography7020022
dcterms.bibliographicCitation.journaltitle
Tomography
dcterms.bibliographicCitation.number
2
dcterms.bibliographicCitation.originalpublishername
MDPI AG
dcterms.bibliographicCitation.pagestart
238
dcterms.bibliographicCitation.pageend
252
dcterms.bibliographicCitation.volume
7
refubium.affiliation
Charité - Universitätsmedizin Berlin
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.bibliographicCitation.pmid
34201012
dcterms.isPartOf.eissn
2379-139X