dc.contributor.author
Aboushady, Dina
dc.contributor.author
Parr, Maria Kristina
dc.contributor.author
Hanafi, Rasha S.
dc.date.accessioned
2020-12-18T13:42:29Z
dc.date.available
2020-12-18T13:42:29Z
dc.identifier.uri
https://refubium.fu-berlin.de/handle/fub188/29112
dc.identifier.uri
http://dx.doi.org/10.17169/refubium-28862
dc.description.abstract
The design of experiments (DoE) is one of the quality-by-design tools valued in analytical method development, not only for cost reduction and time effectiveness, but also for enabling analytical method control and understanding via a systematic workflow, leading to analytical methods with built-in quality. This work aimed at using DoE to enhance method understanding for a developed UHPLC enantioseparation of terbutaline (TER), a model chiral drug, and to define quality assurance parameters associated with using chiral mobile phase additives (CMPA). Within a response surface methodology workflow, the effect of different factors on both chiral resolution and retention was screened and optimized using Plackett-Burman and central composite designs, respectively, followed by multivariate mathematical modeling. This study was able to delimit method robustness and elucidate enantiorecognition mechanisms involved in interactions of TER with the chiral modifiers. Among many CMPAs, successful TER enantioresolution was achieved using hydroxypropyl β-cyclodextrin (HP-β-CD) added to the mobile phase as 5.4 mM HP-β-CD in 52.25 mM ammonium acetate. Yet, limited method robustness was observed upon switching between the different tested CMPA, concluding that quality can only be assured with specific minimal pre-run conditioning time with the CMPA, namely 16-column volume (60 min at 0.1 mL/min). For enantiorecognition understanding, computational molecular modeling revealed hydrogen bonding as the main binding interaction, in addition to dipole-dipole inside the CD cavity for the R enantiomer, while the S enantiomer was less interactive.
en
dc.format.extent
17 Seiten
dc.rights.uri
https://creativecommons.org/licenses/by/4.0/
dc.subject
quality-by-design
en
dc.subject
quality assurance
en
dc.subject
design-of-experiments
en
dc.subject
chiral separation
en
dc.subject
chiral mobile phase modifier
en
dc.subject.ddc
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::615 Pharmakologie, Therapeutik
dc.title
Quality-by-Design Is a Tool for Quality Assurance in the Assessment of Enantioseparation of a Model Active Pharmaceutical Ingredient
dc.type
Wissenschaftlicher Artikel
dcterms.bibliographicCitation.articlenumber
364
dcterms.bibliographicCitation.doi
10.3390/ph13110364
dcterms.bibliographicCitation.journaltitle
Pharmaceuticals
dcterms.bibliographicCitation.number
11
dcterms.bibliographicCitation.originalpublishername
MDPI
dcterms.bibliographicCitation.volume
13
dcterms.bibliographicCitation.url
https://doi.org/10.3390/ph13110364
refubium.affiliation
Biologie, Chemie, Pharmazie
refubium.affiliation.other
Institut für Pharmazie
refubium.note.author
Die Publikation wurde aus Open Access Publikationsgeldern der Freien Universität Berlin gefördert.
refubium.resourceType.isindependentpub
no
dcterms.accessRights.openaire
open access
dcterms.isPartOf.eissn
1424-8247