id,collection,dc.contributor.author,dc.contributor.firstReferee,dc.contributor.furtherReferee,dc.contributor.gender,dc.date.accepted,dc.date.accessioned,dc.date.available,dc.date.embargoEnd,dc.date.issued,dc.description,dc.description.abstract[de],dc.description.abstract[en],dc.identifier.uri,dc.identifier.urn,dc.language,dc.rights.uri,dc.subject,dc.subject.ddc,dc.title,dc.title.translated[en],dc.type,dcterms.accessRights.dnb,dcterms.accessRights.openaire,dcterms.format[de],refubium.affiliation[de],refubium.mycore.derivateId,refubium.mycore.fudocsId,refubium.mycore.transfer "3e85c3b9-58ed-4651-a324-7a8645a12d84","fub188/13","Hartwig, Christian Alexander","Prof. Dr. A. M. Kielbassa","Prof. Dr. H.-G. Schaller||Prof. Dr. B. Haller","n","2007-03-23","2018-06-07T17:39:18Z","2007-01-31T00:00:00.649Z","2007-01-12","2007","Titelblatt und Inhaltsverzeichnis Einleitung Material und Methoden Ergebnisse Diskussion Zusammenfassung Literaturverzeichnis Anhang","Das Ziel dieser Studie bestand darin die Haftwerte einer Lithiumdisilikat- Keramik an verschiedenen Oberflächen in Form von Aufbaumaterialien (MuliCore; Clearfil) zu ermitteln, welche mit unterschiedlich Methoden vorbehandelt wurden. Schmelz und Dentin dienten als Kontrollgruppen. Die Umsetzung der Thematik erfolgte mit 320 Keramikproben des IPS Empress 2-Systems, welche zum einen mit einem Einschritt- (Variolink II/Excite DSC) und zum anderen mit einem Mehrschritt-Adhäsivsystem (Tetric Flow/Syntac Classic) befestigt wurden. Innerhalb der Aufbaumaterialien gab es drei Gruppen, bestehend aus einer Kontrollgruppe ohne Vorbehandlung, einer Gruppe, welche für 10 s mit 9,5%igem Fluorwasserstoff (Ultraetch; Ultradent) und einer Gruppe, die mit dem CoJet- System (3M Espe) vorbehandelt wurden. Mit der Zwick-Universalprüfmaschine (Prüfgeschwindigkeit 0,5 mm/min) wurden die Haftwerte einerseits initial nach 24 h Wasserlagerung (n=10) und andererseits nach einer thermozyklischen Belastung (n=10; 2000 Zyklen, 5-55 °C, 30 s) bestimmt. Die an der natürlichen Zahnhartsubstanz und den mit dem CoJet-System vorbehandelten Gruppen entstanden Haftwerte waren verglichen mit den unbehandelten und mit Fluorwasserstoff behandelten Gruppen erheblich höher (p<0.05; Tukey-B). Somit sollten großflächige Aufbaufüllungen zur Gestaltung einer idealen Kavität für die Präparation von vollkeramischen Restaurationen aufgrund der geringeren Haftwerte zur Keramik kritisch hinterfragt werden, sofern eine stabile provisorische Versorgung des Zahnes gewährleistet ist. Sollte eine Aufbaufüllung unverzichtbar sein, kann die Haftung durch die Vorbehandlung mit dem CoJet-Gerät erhöht werden.","The aim of this study was to evaluate the shear bond strengths of pre- and untreated resin core materials to lithium disilicate ceramics. Bond strengths to dental hard tissues served as controls. Ceramic cubes (IPS-Empress 2) were luted either with a one-step (Variolink II/Excite DSC) or multiple-step total etching bonding system (Tetric Flow/Syntac Classic) to ground surfaces of human enamel, dentin, and resin core materials (Clearfil Core, MultiCore). Resin core materials were additionally pretreated with hydrofluoric acid (HF) or were silica-coated (CoJet System). Shear bond strengths were determined after 24-hour water storage (n=10) and thermocycling (TC) (n=10; 2000 cycles, 5 55°C, 30 seconds). Bond strengths to enamel, dentin, and silica-coated composites were significantly higher compared to untreated and HF-pretreated composites (p<0.05; Tukey B). Silica coating of the composite resins significantly increased the bond strength to ceramics (p<0.05; Tukey B). Due to the lower bond strength values of ceramics to untreated composite resins (as compared to enamel and dentin), any indication for a resin core build-up prior to the preparation of a ceramic restoration should be considered carefully.","https://refubium.fu-berlin.de/handle/fub188/4108||http://dx.doi.org/10.17169/refubium-8308","urn:nbn:de:kobv:188-fudissthesis000000002816-2","ger","http://www.fu-berlin.de/sites/refubium/rechtliches/Nutzungsbedingungen","shear bond strengh||Pre-treatment||lithium-disilicate ceramic","600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit","Haftung einer Lithiumdisilikat-Keramik an verschiedenen Oberflächen vor und nach thermozyklischer Belastung","Shear bond strengths of different substrates bonded to lithium-disilicate ceramics","Dissertation","free","open access","Text","Charité - Universitätsmedizin Berlin","FUDISS_derivate_000000002816","FUDISS_thesis_000000002816","http://www.diss.fu-berlin.de/2007/78/"